Reinstall, After any service, make sure of the following, Sealer film – Sharp Carousel R-305KS User Manual

Page 31: R305ks

Advertising
background image

R305KS

11 – 7

16.Now, door screen is free.

17.Remove the door decoration from the door frame by straightening

all tabs of the door decoration.

18.Now, the door decoration is free.

2. REINSTALL

1. Re-install the door screen and the door decoration to door frame.

2. Reinstall the latch spring to the latch head. Reinstall the latch

spring to the door frame. Reinstall latch head to door frame.

3. Reinstall door panel to door frame by fitting ten (10) tabs of door

frame to ten (10) holes of door panel.

4. Put sealer film on door panel. Refer to “Sealer Film” about how to

handle new one.

5. Catch two (2) pins of door panel on two (2) hole of upper and lower

oven hinges

6. Re-install choke cover to door panel by pushing.

NOTE: After any service to the door;

1) Make sure that door sensing switch and secondary interlock

switch are operating properly. (Refer to chapter “Test Proce-
dures”.).

2) An approved microwave survey meter should be used to

assure compliance with proper microwave radiation emission
limitation standards.

3. After any service, make sure of the following:

1. Door latch heads smoothly catch latch hook through latch holes

and that latch head goes through center of latch hole.

2. Deviation of door alignment from horizontal line of cavity face plate

is to be less than 1.0mm.

3. Door is positioned with its face pressed toward cavity face plate.

4. Check for microwave leakage around door with an approved micro-

wave survey meter. (Refer to Microwave Measurement Procedure.)

NOTE: The door on a microwave oven is designed to act as an

electronic seal preventing the leakage of microwave
energy from oven cavity during cook cycle. This function
does not require that door be air-tight, moisture (conden-
sation)-tight or light-tight. Therefore, occasional appear-
ance of moisture, light or sensing of gentle warm air
movement around oven door is not abnormal and do not
of themselves indicate a leakage of microwave energy
from oven cavity.

Figure C-6. Door Replacement

4. SEALER FILM

1. Put the adhesive tape on the backing film of the sealer film as

shown in Fig. C-7

2. Tear the backing film by pulling the adhesive tape.

3. Put the pasted side of the sealer film on the door panel

Figure C-7. Sealer film

Pin

Pin

Upper
Oven Hinge

Upper Oven
Hinge

Lower Oven

Hinge

Lower
Oven Hinge

Slit choke of
door panel

Choke Cover

Sealer film

Backing film

Adhesive tape

Advertising