CoNNECTING a HUNTEr “ClIk” WEaTHEr sENsor

A Hunter weather sensor or other micro-switch type weather

sensors can be connected to the X-Core. The purpose of this sensor

is to stop automatic watering when weather conditions dictate.
1.

Remove the metal jumper plate that is attached across the two

SEN terminals inside the controller.

2. Connect one wire to one SEN terminal and the other wire to the

other SEN terminal.

When the weather sensor has

deactivated automatic watering,

the OFF, and

icon will appear

on the display.

Testing the Weather sensor

The X-Core provides simplified testing of a rain sensor when the

sensor is wired into the sensor circuit. You can manually test proper

operation of the rain sensor by running a MAnUAL CyCLe or by

activating the system using the One touch MAnUAL stARt (see

page 22). During the Manual cycle, pressing the test button on the

Mini-Clik

®

will interrupt watering.

manually bypassing the Weather sensor

If the rain sensor is interrupting irrigation,

you can bypass it by using the bypass

switch on the front of the controller. Slide

the switch to the sensOR ByPAss position

to disable the rain sensor from the system

to allow for controller operation. You can

also bypass the weather sensor for manual

operation by using the MAnUAL – One stAtIOn function.

the Bypass switch does not affect the seasonal Adjust update
when using solar sync sensor.