Advanced features, Programmable sensor override, Test program of all stations – Hunter X-CORE User Manual

Page 25: Hunter quick check™ diagnostics

Advertising
background image

23

aDVaNCED fEaTUrEs

programmable sensor override

The X-Core allows the user to program the controller so that the

sensor disables watering on only desired stations. For example,

patio gardens that have pots under overhangs and roofs may not

receive water when it rains and will continue to need to be watered

during periods of rain. To program sensor override:
1. Turn the dial to the RUn position.
2. Press and hold the button down while turning the

dial to stARt tIMes position.

3. Release the

button. At this point, the display will

show the station number, ON, and the icon, will

be flashing.

4. Press the

or button to enable or

disable the sensor for the station shown.

ON = Sensor enabled

(will suspend irrigation)

OFF = Sensor disabled (will allow watering)

5. Use the or buttons to scroll to the next

station that you would like to program the

sensor override.

NoTE: the controller default is for the sensor to
disable watering on all zones when rain occurs.

When the X-Core receives an input from the sensor to disable

watering, the display will indicate those stations that have been

programmed to override the sensor. A station that is running in

the sensor override mode will flash the and icons alternately.

Test program of all stations

The X-Core allows the user a simplified method for running a

test program. This feature will operate each station in numerical

sequence, from the lowest to the highest.
1. With the dial in the RUn position, press and hold the

button. The station number will be displayed and the time

will be flashing.

2. Use the

or buttons to set the run time from 1 to 15

minutes. The run time needs to be entered only once.

3. After a 2 second pause, the test program will start.

Hunter Quick Check™ Diagnostics

This feature allows you to quickly diagnose wiring problems with

your controller. Instead of having to check each field wiring circuit

for potential problems, you can use the Hunter Quick Check circuit

test procedure. To initiate the Quick Check test procedure:
1. Press the

, , , and buttons simultaneously. In the

standby mode, the LCD will display all segments.

2. Press the

button once to begin the Quick Check procedure.

Within seconds, the system searches all stations for detecting

any circuit problems. When a field wiring short is detected, an

ERR symbol preceded by the station number will momentarily

flash on the display. After the Quick Check completes running

the circuit diagnostic procedure, the controller returns to the

automatic watering mode.

RUN

Sensor Enable

Sensor Disabled