TroUblEsHooTING GUIDE

problem

Causes

solutions

The controller is continuously watering

Too many start times have been

programmed

Only one start time is necessary to activate a program

(refer to Setting the Program Start Times on page 18)

There is no display

Check AC power wiring

Correct any errors

The display reads “No AC”

There is no AC power present (the

controller is not receiving any power)

Check to see if the transformer is properly installed

Display reads “Off,

The rain sensor is interrupting irrigation

or the sensor jumper has been removed

Slide the rain sensor bypass switch to the BYPASS

position to bypass the rain sensor circuit, or reinstall

the jumper

Rain sensor will not shut off the system

• Defective rain sensor
• Jumper was not removed when sensor

was installed

• Stations have been programmed to

override the sensor

• Verify operation of rain sensor and proper wiring
• Remove jumper from the sensor terminals
• Reprogram the sensor override to enable the sensor

(see page 11)

Frozen display, or showing incorrect

information

Power surge

Reset the controller per page 24 “Clearing Controller

Memory/Resetting the Controller”

Display shows “ERR” with a number

(1 to 8)

Short in valve wiring circuit, or faulty

solenoid on the station number

indicated

Check wire circuit or solenoid for the valve number

indicated. Repair short or replace solenoid. Press any

button to clear the “ERR” from the display

Display shows “P ERR”

• Faulty pump relay or master

valve wiring

• Incompatible or defective relay or

solenoid

• Under sized wire to the pump relay

or master valve

• Check wiring to relay or master valve solenoid. Press

any button to clear the “P ERR” from the display

• Check electrical specification for the pump relay.

Do not exceed controller's electrical rating. Replace

if defective

• Replace wire with larger gauge wire