3

ENG

mounTIng THe ConTroller To THe Wall

1. Secure one screw into the wall. Install screw anchors if

attaching to drywall or masonry wall.

2. Slide the keyhole on top of the controller over the screw.
3. Secure the controller in place by installing screws in the

holes below the terminal strip.

ConneCTIng ValVes

NOTE: The XCH operates DC latching solenoids

only (order Hunter P/N: 458200). 24 VAC solenoids

will NOT operate with the XCH. DC solenoids can

be easily identified by red and black leads. The red

lead is attached to the station output, while the

black lead is attached to the common wire.

1. Route valve wires between the control valve location and

controller.

2. At valves, attach a common wire to the black solenoid

wire on all valves. Attach a separate control wire to the

remaining red wire of each valve. All wire connections

should be done using waterproof connectors.

3. Route the valve wires through the conduit. Attach the

conduit through the bottom right side of the controller.

4. Secure the valve common wire to the C (Common) screw

on the terminal strip. Attach each of the individual valve

control wires to the appropriate station terminals and

tighten their screws.

WIre sIZe

dIsTanCe from ValVe

To ConTroller

18 AWG

550 feet

16 AWG

870 feet

14 AWG

1380 feet

12 AWG

2200 feet