Check microwave assembly, Adapting microwave blower for recirculation, Adapting microwave blower – GE spacemaker xl1800 User Manual

Page 20: For recirculation –21, Installation instructions, Adapting microwave blower for recirculation c4. 20, Check microwave assembly c3

Advertising
background image

AFTER: Fan Blade
Openings Facing
Forward

5

4

3

6

ADAPTING MICROWAVE
BLOWER FOR RECIRCULATION

C4.

20

NOTE:

The exhaust adaptor with damper is not

needed for recirculating models. You may want to

save them for possible future use.

Carefully pull out the blower unit. The wires

will extend far enough to allow you to adjust the

blower unit.

Roll the blower unit 90° so that fan blade openings

are facing toward the front of the microwave.

Roll

Slide exhaust adaptor to one side and remove it.

Remove and save the screw that holds the blower

motor to the microwave.

Blower Plate

Blower Motor
Screw

Back of

Microwave

Remove

and save

screw that

holds

blower

plate to

microwave.

Lift off the

blower plate

and attached

adaptor from

the microwave.

NOTE:

Make sure wires remain routed in the grooves

of the motor frame.

Installation Instructions

BEFORE: Fan Blade
Openings Facing Up

Damper

Back of

Microwave

CHECK MICROWAVE ASSEMBLY

C3.

Exhaust Adaptor (absent

on models shipped for

recirculation exhaust)

Back of

Microwave

Place the microwave in its upright position, with the

top of the unit facing up.

The microwave oven may be shipped assembled for

top exhaust (adaptor installed) or for recirculation

exhaust (adaptor absent).

If the microwave was shipped for recirculation

exhaust, skip to C5. If shipped for top exhaust,

proceed with C4.

1

2

Advertising