Bryant GAS FIRED 394U User Manual

394u, Brqant, Gas fired upflow furnace

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

brqant

GAS FIRED

UPFLOW FURNACE

P

D i t i

S

394U

Size 80

Series B

PDS 394U.80.2 4/25/67

o>

o>

CO

o

o

CO

CO

Q

a.

c

_o

+-•

to

_o

"a.

Q.

<

_0

ill

CD

o

<1>

a>

to

-c;

CJ

CO

c

o

eg

'o

<u

Q.

CO

CLEARANCES FROM COMBUSTIBLES

In "large” rooms

6" from casing & vent hood

1" from sides & top of supply plenum

In confined spaces

0" from casing sides, rear & bottom

6" from casing front & type C vent connector

3 " from top & sides of uninsulated supply

plenum

SHIPPING WEIGHT

160 lbs.

STANDARD GAS CONTROL OPTIONS

100% shut-off automatic pilot; Bryant

diaphragm valve; transformer.
Bryant diaphragm valve; Bryant auto­

matic pilot; gas pressure regulator; trans­
former.

100% shut-off for natural gas. Same as

D4 except uses thermocouple pilot and
pilot relay.

HEATING RATINGS AND CAPACITIES

Control

Type

Gas

D2

LPG

D4

City

D5

City

Ratingi Inputs BTUH

80,0003

Output BTUH

64,000

^Ratings are for elevations up to 2000 ft.; for higher altitudes,

reduce ratings 4 % for each 1000 ft. above sea level.

^20% reduction in input allowed.
^For LP Gas, model designated 80-V-394, A.G.A. Input 75,000,

Output 60,000.

COMPONENT INFORMATION

Motor—Type L or M—4 Speed

Vs HP (Sh. Pole)

Power Supply

120-60-1

Full Load Amps_

6.3

Speed & Rotation

1050 CCW*

Motor—Type E—4 Speed

M HP (PSC)

Power Supply

120-60-1

Full Load Amps

5.4

Speed & Rotation

1075 CCW*

Blower Wheel Dia. & Width

10"

X

6"

Bore—Direct Drive

Vi"

Filter—Fiberglass * *

Inlet At Bottom

14"

X

25"

X

1"

External Filter Rack

14"

X

25"

X

1"

Internal Side Filter

14"

X

25"

X

1"

Rear Drop Duct

14"

X

25"

X

1"

OPTIONAL

REAR DROP

DUCT FOR

BASEMENT

APPLICATIONS

DRIVE TYPES

L —Multi-speed direct drive heating-
M—Multi-speed direct drive heating-

evaporator blower motor relay

E —Multi-speed direct drive heating^m,^imum cooling with

evaporator blower motor rela;^

-mimmum cooling

-minimum cooling with

Gas Supply N:^ f^fccal^,

f %

VPrlpane,*,.,

^ VA

Electric Supply—SDirari:

^

>20.-60-1

Branch Circuit AWG/*^

^

\4

\

Fuse Size XW' AM3K\^

/ i5>i

Control Circuit Pow^r i^ig.iK'*l^ \

^ 1 V'l

Type L \

V W'''

1 Mo.r" i

Type M or E

\

'

Flue Size \

^4 (Oval)

Duct—Inlet at bottom

\V

22M

X

12M

Inlet ext. filter rack H x W

12

X

23

Inlet drop duct D x W

12

X

14Ji

Discharge D x W

20 X 14^

*External to unit

CONTROL INFORMATION

Burners (Steel Slotted Port)

3

Orifice DrUl Size Prop.

54

Nat.

40

D2 Control (Prop.) Regulator

None Required

Valve

, A641

Escapement Orifice Drill Size

-'80

Pfiot—MH Q314A

.011 Orifice

D4 Control (Nat.) Regulator

Comb. Thermae VR-1

Valve

A641

Escapement Orifice Drill Size

80

Pilot—732

.016 Orifice

D5 Control (Nat.) Regulator

Comb. Thermae VR-1

Valve

A641

Escapement Orifice Drill Size

80

Pfiot—MH Q314A

.018 Orifice .

*Rotation viewed from end opposite shaft

**Use multi-velocity filters above 875 CFM

Manual Shut-off Cock and Pilot Cock are standard equipment.

Supplied as separate parts except where included as integral
part of the combination regulator.

Advertising