Installation Instructions

POWER HUMIDIFIER

905D

Series D

bri|ant

INTRODUCTION

The Bryant Model 905D Duct Humidifier is shipped

complete and ready for mounting to the supply air

duct of the heating unit. The humidifier is connected

electrically to the heating unit blower circuit and

operates only when the blower is running on heating

cycles. The water supply connects to the float-valve

assembly, mounted in the upper front corner of the

humidifier pan. The waterflow is automatically con­

trolled by the float.

We recommend the use of a humidistat with the

Model 905D because of its high humidification

capacity.

The Bryant Humidifier includes the following:

Disc assembly

Drive motor

Water pan

Water valve and float assembly

Sight window

Drain plug

Paper template

Parts bag containing: power supply cord, latches,

mounting bracket, and saddle valve assembly.

IMPORTANT: Read before installing.

1. Check local codes and ordinances for

requirements.

2. Check power supply to be sure it corresponds to

that specified on the rating plate (115-60-1).

Installation of the Model 905D Humidifier comprises

the following steps (sections):

I. Locating the Unit

II. Mounting the Unit

III. Connecting Water Supply

IV. Connecting Electrical Supply

V. Start-up and Adjustment

VI. Service and Maintenance

I. LOCATING THE UNIT

The unit should be located on a supply air duct

having a minimum width of 12 inches. For best

operation, locate unit where air is evenly distributed

in the duct. The duct should be level, within 1/4 inch

per foot at the point of installation.

NOTE: The minimum size duct on which the

humidifier can be mounted is 8 inches high by 12

inches wide. Bryant’s Model 905D Humidifier is

designed for indoor installation only.

Cancels: 39905D1 Rev 4

|

39905D4

4/15/73

I

Figure 1—Model 905D Power Humidifier

II. MOUNTING THE UNIT

,1. Tape paper template to duct at desired location;

proceed to cut opening and drill holes per in­

structions printed on template.

2. Install mounting bracket and latches. See

Figinre 3.

3. Slide humidifier pan rim, one without foam tape,

into mounting bracket. Lift unit into place and

turn latches so they catch rim of humidifier.

4. Check for air leaks. Use stiffeners around duct

opening to straighten duct if necessary.

III. CONNECTING WATER SUPPLY

NOTE: Unsoftened water is recommended.

1. Tap off nearest cold water line with self-piercing

saddle valve provided. Follow directions on

packet for installing saddle valve.

2. For connecting main water supply to humidifier

pan, use Bryant’s optional tubing kit P/N

65193D01 (instruction included in kit). In a few

cases, because of local codes, it may be necessary

to use 1/4-inch copper tubing rather than plastic

tube supplied in Bryant tubing kit. Tubing line

should be purged with water before connecting to

float-valve assembly.

3. A drain line can be connected to 1/2-inch OD

outlet located in right-hand corner of humidifier

pan when facing humidifier motor. Run line to

an open drain.