Cooper Lighting MU/TLU User Manual

Installation instructions, Talon medium, Sheet 1 of 3

Advertising
background image

Tools Required Socket, 5/16" Socket, 3/4" Deep Well Socket, Electrical
wiring tools.

NOTE: These luminaires are designed for outdoor lighting
services, and should not be used in area of limited ventilation
or in high ambient temperature enclosures. Construction is
suitable for down lighting only. Best results will be obtained
if installed and maintained according to the following
recommendations.

1. Remove housing assembly and arm components from carton. Remove

power tray if fixture is not hard mount version.

2. With the fixture on its back, open and remove door by pressing thumb

latches outward at the same time, open the door and lift it from the
hinges. FIG. 1

3. Run the threaded rods (2) through the center of the semi-enclosed hole

details in the arm extrusion. To help orient the arm correctly with the
housing, please note that one end of the extruded arm has an angled cut
and the other has a perpendicular cut with two drain notches located on
the bottom. If assembling to a round pole, use the round pole adapter
with the drain channels located at the extruded arm end with the drain
slots. Mate the angled side of the extruded arm to the housing so that
the bottom surface of the extrusion is parallel to the bottom of the
fixture, and the drain notches are facing down and located away from
the housing. FIG. 2 Slide the threaded rods into the interior of the
housing. Attach flat washer, lock washer, and nut into place in the order
shown in FIG. 2. Torque hex nuts to 450 lb/in.

4. If necessary, remove the cap on the pole. Position the housing and arm

to assemble it to the pole. Lower the nut plate into the interior of the
pole as shown. Slide the threaded rods through the pole and thread into
the nut plate until the rod protrudes though the nut plate slightly. Tighten
both nuts located inside of the housing to 30 lb/ft of torque.

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency
during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest
representative.

Talon Medium

Sheet 1 of 3

7/23/08

IMI-687SW

INSTALLATION INSTRUCTIONS

IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE.

WARNING: Risk of Fire/Electric Shock. If not qualified, consult an electrician.
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing.
WARNING: Risk of Burn. Disconnect power and allow fixture to cool before changing bulb or handling fixture.
WARNING: Risk of Personal Injury. Fixture may become damaged and/or unstable if not installed properly. Tighten all fixture components

to their recommended torque values.

WARNING: Risk of Fire/Electrical Shock. Upside down installation can result in overheating or accumulation of water in fixture.

Install right side up.

NOTE: Specifications and dimensions subject to change without notice.

Visit our web site at www.cooperlighting.com

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADW081604

FIG. 1

Latches

FIG. 2

Hardware: Washer,
Lock Washer, and
Hex Nut

Arm

Nut Plate
Fits Inside
of Pole

Round Pole
Adapter
(Optional)

Mounting Rod (2)