Aiphone PS-1225UL User Manual

Al phon e, Ps-1225, Ps-1225ul

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

PS-1225 MANUAL E PM 0303®

® Al PHON E

r"

DC POWER SUPPLY FOR INTERCOM

Models;

PS-1225

^ without AC plug

PS-1225UL

^ ULJCSA Listed

PS-1225S

This product is designed exclusively for use with Aiphone intercom Systems.

INSTALLATION MANUAL

PRECAUTIONS

Genera! prohibitions Prohibitions to dismantie the unit Q General precautions

A WARNING

(Negligence could result in death or serious injury.)

Do not connect the unit with any non-specified power source. Fire or electric shock could result. ®
• Do not connect any terminal on the unit to AC power lines. ®
• Keep AC cord away from being marred or crushed. Fire or electric shock could result.®
• Do not plug or unplug with wet hands. Electric shock could result.0
• Do not make the wires or DC output terminals shorted. Fire or unit trouble could result.0
• Do not dismantle or alter the unit. Fire or electric shock could result. 0
• Keep AC plug away from moisture or dust. Fire could result.O

A CAUTION

(Negligence could result in injury or damage to property.)

• Do not install or make any wire terminations while power supply is plugged in. It can cause

electrical shock or damage to the unit.

®

• Before plugging in the unit, make sure the wires are not crossed or shorted, it can cause fire

or electric shock.

M

• Do not install the unit in any of the foilowing locations, as it may cause the system to malfunction; 0

High or extreme cold temperature areas: under direct sunlight, near equipment that varies in

temperature, in front of air-conditioner, inside a refrigerated area, etc.

Places subject to moisture or humidity extremes, such as bathroom, cellar, greenhouse,etc.

• Places subject to environmental conditions, such as dust, oil, chemicals, salt, etc.
• Places subject to constant vibration or impact.
• Places subject to steam or smoke.(near heating equipment or cooking surfaces)
• Places subject to direct rain or outdoors.

Package contents

• Power supply (PS-1225,

PS-1225UL or PS-1225S)

• AC cord & plug (except PS-1225)
• Mounting bracket
• Packet of screws
• INSTALLATION MANUAL

A

IMPORTANT:

in case your System and/or
Power Supply malfunctions or is

in apparent troubie,unplug the
Power Supply from AC outlet.

AC cord inlet

T t

Protection cover

Grounding terminal

DC output terminals

Type of plug varies by model

AC cord requirements (for PS-1225)

> Rating: 125V, 2A (for use with 100-125V AC)

250V, 2A (for use with 200-240V AC)

• Cord length: min. 1.8m (S'), max. 2m (67").
•Type: Must comply with requirements set out by the Safety Approval/Certification Organization In each country of use.
• AC cord iniet: Specified EN60320 or equivalent.
• Employ a plug in shape and ratings matched with AC outlet tb be used.

Plug configuration

UL LISTED

UL LISTED

Usage

North American

North American

AC cord

Nominal voltage

& current rating

120V, 60Hz,

2A min.

240V, 60Hz,

2A min.

Plug configuration

Usage

AC cord

Nominal voltage

& current rating

Universal

European

230V, 50Hz,

2A min.

United Kingdom

■i..

230V, 50Hz,

2A min.

Australian

240V, 50Hz,

2A min.

-1 -