hydro flame™

Model1H2C

Digital Thermostat

FOR STANDARD FURNACES

& A/C SYSTEMS

ENGLISH, FRANÇAIS

(et Canada)

«Installation «Operation

Effective 9/21/04

THIS THERMOSTAT HAS BEEN DESIGNED TD DPERATE STANDARD AIR CONDITIDNING UNITS IN CONJUNCTION WITH A RV FURNACE.

SPECIFICATIONS

Operating Voltage............................... 9VDC to 18VDC
Current Consumption at 12V0C ........................ 100mA
Operating Temp.....................................-40F to +185F
Room Temp. Range ................................+55F to +90F
Room Temp. Display Range .................... +35F to +99F
Thermostat Accuracy.......................................... t/- 1F
Switching Capability A/C............................up to 24 VAC

uispiay Kioaesei

(max. 2 AMPs)

•Note: Move jumper to
positions 3 and 4 for RVP
Unit. Discard jumper for
Dometic”.

SLIDE SWITCH

LEFT RIGHT

SCROLL ORDER OF

DISPLAYED MODES

OPERATION

COOL OFF HEAT FAN

Furnace Operation

HI

Furnace cycles to satisfy set point.

COOL OFF HEAT FAN

Air Conditioner Operation

AU

Air conditioner automatically switches compressor and high and

low speed fan when cycling to satisfy set point.

HI

Air conditioner compressor and high speed fan cycle to satisfy
set point.

LO

Air conditioner compressor and low speed fan cycle to satisfy
set point.

COOL OFF

HEAT FAN

Fan Operation

HI

Air conditioner fan runs at high speed to circulate air.

LO

Air conditioner fan runs at low speed to circulate air.

COOL OFF HEAT FAN

Off

OF

No operation occurs.

PMtSW MM

THERMOSTAT INSTALLATION
Thermostat js very sensitive,

handle

WITH CARE AT ALL TIMES.

Locate thermostat 48” to 54" above

floor on an

INTERIOR

Wall. Pick a dry

area where air circulation is good.

EXTERIOR

wall location must have a

3/4" spacer between thermostat and
exterior wall.

1. Be sure all electrical power has

been disconnected from the air
conditioner, furnace and the
power supply.

2. Do not install the thermostat

where there are unusual heating
conditions: such as direct
sunlight, heat producing
appliances (television, radio, wall
lamp, etc.) or a furnace or air
conditioner supply register.

3.

AHACHING THE WALL THERMOSTAT.

Separate the thermostat body
from the sub-base by gently
squeezing the top and bottom,
connecting wiring per
requirements. Attach thermostat
sub-base to the wall at desired
mounting location.

WIRING REQUIREMENTS FOR ATWOOD THERMOSTAT