Chromalox CMB-3A User Manual

Installation, operation, Type cmb electric steam generator, Renewal parts identification

Advertising
background image

(Supersedes PQ400-8)

PQ400-9

3001H

161-048643-001

JULY, 2009

4

and

Installation, Operation

RENEWAL PARTS IDENTIFICATION

Type CMB Electric Steam Generator

0 – 90 PSI

© 2010 Chromalox, Inc.

Output

Single Phase

Three Phase

Lbs./Hr.

Power

Power

Vol.

AT †

Amperes

CCT.

Amperes

CCT.

Model

kW

(Gals.)

212°F

Volts

Drawn

Diag.

Drawn

Diag.

3

1.6

9

120

25

1

NA

NA

CMB-3A

3

1.6

9

208

14.4

2

8.3

3

3

1.6

9

240

12.5

2

7.2

3

3

1.6

9

480

6.3

2

3.6

3

6

6

18

208

28.8

4

16.7

8

CMB-6A

6

6

18

240

24

4

14.4

8

6

6

18

480

125

4

7.2

8

9

6

27

208

43.3

6

25

8

CMB-9A

9

6

27

240

37.5

5

21.7

8

9

6

27

480

18.8

4

10.8

8

12

6

36

208

57.7

7

33.3

8

CMB-12A

12

6

36

240

50

7

28.9

8

12

6

36

480

25

5

14.4

8

15

6

45

208

72.1

7

41.6

9

CMB-15A

15

6

45

240

62.5

7

36.1

8

15

6

45

480

31.2

5

18

8

Specifications —

GENERAL

WARNING: Hazard of Electric Shock. Any installa-
tion involving electric generators must be effec-
tively grounded in accordance with the National
Electrical Code to eliminate shock hazard.

1. Locate unit on level floor or platform.
2. Connect water line to tagged fitting on the water control feeder.
3. The incoming water supply must be 10 pounds greater than the

operating pressure. Otherwise, a high pressure feed (pump)
must be used.

4. Wire unit following wiring diagrams supplied. (See recom-

mendations on safety switches and fusing.)

5. Connect steam line with an outlet valve to boiler steam outlet.

Chromalox recommends using a globe valve one pipe size
smaller than steam line to limit any pressure drops (surges) that
may occur during start-up.

6. Open all gauge valves and steam outlet valve. Keep drain valve

closed.

7. Turn on watter supply; water will reach operation level auto-

matically.

8. Close steam outlet valves.
9. Set thermostat for desired steam pressure (see Table 1).
10. Turn boiler switch to ON position, pilot light will go on.

Generator will Build up to desired
pressure and shut off automati-
cally.

11. Open steam outlet valves and

use steam as needed.

12. Generator should be blown

down daily (see Blowdown
instructions).

13. Chromalox generators are pretest-

ed before shipment. No internal
wiring or piping is required.

14. Substitution of components or

modification of wiring systems
without consult of manufacturer
voids the warranty.

15. Power must be off when genera-

tor is drained.

16. Purchaser should use a safety

switch between the main power
source and the steam generator.
The safety switch should use cir-
cuit breakers or fuses.

CMB-3A

† Assuming Feedwater at 50°F.
Note — All Models listed with Underwriters Laboratories Inc.

Gauge Pressure

Temperature

(psig)

(°F)

0

212

1

216

2

219

3

222

4

224

5

227

6

230

7

232

8

235

9

237

10

240

15

250

20

259

25

267

30

274

35

281

40

287

45

292

50

298

55

303

60

307

65

312

70

316

75

320

80

324

85

328

90

331

Table 1 —
Temperature-Pressure
Relationship for Steam

Boiler Serial # . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Circuit Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Model # . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control Circuit Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

National Board # . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Amps. . . . . . . . . . . . . . . Phase . . . . . . . . . . . Cy . . . . . . . . . . . . . . .

IMPORTANT – This data file contains the National Board Registration Certificate approving your generator. It must be kept near the generator at all times.