6. Maintenance

Interlock

3. Remove the lamp.

(1)Loosen the two screws securing the lamp until the phillips screwdriver goes into a freewheeling condition. The

two screws are not removable.

NOTE: Do not remove any screws except these two screws.

(2)Remove the lamp by holding it.

NOTE: There is an interlock on this case to prevent the risk of electrical shock. Do not attempt to circumvent this interlock.

1

1

2

3

2. Remove the lamp cover.

(1) Press firmly and slide the lamp cover by 1 cm (0.4”)

• Do not force to pull the lamp cover

(2) Push two catches on both sides lightly

ቢ to slide the lamp cover slowly ባ until the catch is seen and then

pull up the lamp cover

ቤ.

CAUTION:

DO NOT TOUCH THE LAMP immediately after it has been used. It will be extremely hot. Before handling,
turn the projector off, wait until the cooling fans stop, turn off the main power switch, disconnect the power
cord and then allow at least 60 minutes for the lamp to cool.