Aiphone PS-1820S User Manual

Ps-1820, Ps-1820ul, Ps-1820s

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

PS-1820 MANUAL E PM 0902

®

O

a i p h o n e

DC POWER SUPPLY FOR INTERCOM

Models;

PS-1820

^ without AC plug

PS-1820UL

^ UL/CSA Listed

PS-1820S

5

Listed

This product is designed exclusively for use with Aiphone Intercom Systems.

INSTALLATION MANUAL

PRECAUTIONS

^ General prohibitions ^ Prohibitions to dismantie the unit o Generai precautions

A

warning

(Negligence could result In death or serious injury.)

Do not connect the unit with any non-specified power source. Fire or electric shock could result. 0

• Do not connect any terminal on the unit to AC power lines. 0
• Keep AC cord away from being marred or crushed. Fire or electric shock could result.0
• Do not plug or unplug with wet hands. Electric shock could result.0
• Do not make the wires or DC output terminals shorted. Fire or unit trouble could result.0
• Do not dismantle or alter the unit. Fire or electric shock could result. 0
• Keep AC plug away from moisture or dust. Fire could result.0

A CAUTION

(Negligence could result in injury or damage to property.)

• Do not install or make any wire terminations while power supply is plugged in. It can cause

electrical shock or damage to the unit.

0

• Before plugging in the unit, make sure the wires are not crossed or shorted. It can cause fire

or electric shock.

O

• Do not install the unit in any of the following locations, as it may cause the system to malfunction; 0

• High or extreme cold temperature areas: under direct sunlight, near equipment that varies in

temperature, in front of air-conditioner, inside a refrigerated area, etc.

• Places subject to moisture or humidity extremes, such as bathroom, cellar, greenhouse,etc.
• Places subject to environmental conditions, such as dust, oil, chemicals, salt, etc.
• Places subject to constant vibration or impact.
• Places subject to steam or smoke.(near heating equipment or cooking surfaces)
• Places subject to direct rain or outdoors.

Package contents

• Power supply (PS-1820,

PS-1820ULor PS-1820S)

' AC cord & plug (except PS-1820)
• Mounting bracket
• Packet of screws
• INSTALLATION MANUAL

Protection cover

Grounding terminal

DC output terminals

Type of plug varies by model

I AC cord requirements (for PS-1820)

• Rating: 125V, 2A (for use with 100-125V AC)

250V, 2A (for use with 200-240V AC)

• Cord length: min. 1.8m (6'), max. 2m (67”).
• Type: Must comply with requirements set out by the Safety Approval/Certification Organization in each country of use.
• AC cord inlet: Specified EN60320 or equivalent.
• Employ a plug in shape and ratings matched with AC outlet to be used.

Plug configuration

Usage

AC cord

Nominal voltage

& current rating

UL LISTED

North American

120V, 60Hz,

2A min.

UL LISTED

North American

240V, 60Hz,

2A min.

Plug configuration

Usage

AC cord

Nominal voltage

& current rating

Universal

European

230V, 50Hz,

2A min.

United Kingdom

230V, 50Hz,

2A min.

€7”

Australian

240V, 50Hz,

2A min.

1 -

Advertising
This manual is related to the following products: