[ 1 ] Fully Discharging (Refresh) and then Charging

(1)

Power on the CU-6001. The POWER LED comes on.

(2)

Load a Ni-MH battery cartridge into the CU-6001 from the battery cartridge slot.

The CU-6001 flashes the CHG2 LED at 0.4-second intervals and starts discharging
the cartridge. The discharging time differs depending upon the battery condition,
but never more than three hours.

Upon completion of discharging, the CHG2 LED comes to stay on and the CU-
6001 starts charging.

After approx. ten hours of charging, the CHG2 LED starts flashing at 2-second
intervals, indicating that the charging is completed.

(3)

Take out the battery cartridge.

DATA

CHG2

POWER

CHG1

DATA

CHG2

POWER

CHG1

DATA

CHG2

POWER

CHG1

DATA

CHG2

POWER

CHG1

DATA

CHG2

POWER

CHG1

Discharging & Charging Operations and LED Indication

Operator's Action

Power on the CU-6001.

Load a battery cartridge

into the CU-6001.

After discharging

After approx. 10 hours

Take out the battery

cartridge.

CU-6001 Status

On standby

Discharging

Ordinary charging

Trickle charging

On standby

LED Indication

ON

ON

ON

ON

ON

ON

OFF

Flashing at
0.4-second
intervals

Flashing at
2-second
intervals