1270 POWER AMPLIFIER

OPERATING

INSTRUCTIONS

No user-serviceabte vorts inside. Hazardous uoltme may be

l

'

ji

-

CAUTION:

,

cauniered witkiit fhedmssis, InstaHahon and bervwc mjormatum

within this document is for use only by ALTECsoiind contractors, fnclonj authorized

liHirmnty stations and quaiified service personnel.

II est enjoint a l'utilisateur de ne yds réparer ïui-même les pièces

IMPORTANT:

. ,

\

,

internes de 1 appareil, des courants a haute tension pouvant pas­

sera l'intérieur du châssis. Tes renséignenien ts indus dans ce doainient son t destinés

uniquement à l'usage des installateurs agréés des systèmes acoustiques ALTEC, des

centres de réparation

sous

garantie autorisés, ainsi que du personnel d'entretien

qualifié-

INTR0DUCT10N

The ALTEC LANSING Model 1270 Power

Amplifier provides continuous high power
demand where uninterrupted operation is

requisite. Designed to protect itself and the
acoustic elements it drives, the Model 1270

represents 800 + watts of controlled power.

Two channels may be operated independ­

ently, in parallel or in bridged configuration
to deliver up to 400 watts per channel at

less than 0.05% THD from 20 Hz to 20 kHz.

Peak Error Computer

The amplifier is provided with a peak/error

computer that compares channel input and

output signals and detects any output
errors. Detection of any peak/error causes
the appropriate peak/error indicator to illu­

minate. Output anomalies detected include
excessive voltage, excessive current (load),
excessive slew rate, and any other signifi­
cant difference between the channel input
and output signal.

Amplifier Protection

The amplifier output is continuously mon­

itored to guard against excessive current

drain. An instantaneous VI limiter restricts
output to 400 VA ±45° phase shift. The
amplifier is additionally protected against

excessive operating temperature; logic cir­
cuitry automatically overrides low-speed
fan operation and locks to the high fan
speed mode. If operating temperature

remains excessive, the load is discon­
nected by a relay and the protection indica­
tor illuminates. When temperature falls to
safe operating conditions, the amplifier
automatically resumes operation.

Load Protection

The load is protected from transients dur­

ing startup and shutdown of the amplifier.
During startup, the load remains discon­
nected through a relay during a three-

FRONT PANEL CONTROLS AND FEATURES

second delay period. During shutdown or

loss of power, the load is instantaneously
disconnected by the relay. The load is simi­

larly protected against amplifier failure,

such as dc voltage at the output.

Item

Name

Peak/Error
Indicators

Protection
Indicator

POWER
Indicator

POWER Switch

CHANNEL
Volume
Controls

Function/Description

Illuminate when excessive voltage, current or slew rate ap­
pears at the output terminals.

Illuminates when protection circuitry operates to prevent dam­

age to the amplifier or load.

Illuminated when primary ac power is applied to the amplifier.

Applies primary ac power to the amplifier.

Adjust gain of LEFT and RIGHT channels. Rotate clockwise to

increase gain.

LANSING

Specifications and components subject to change without

notice. Overall performance will be maintained or

iTTzproLieci.

1515 S. Manchester Ave., Anaheim, Calif. 92803

42-02-045539-01

LITHÛ IN U.S.A. 68MM

Advertising