Radio Frequency Controlled, 120 VAC,

Wall Mounted 3-Way Switch, Release1.1

ZRW153

HomePro

RF Home Automation

ZRW153 WALL MOUNTED SWITCH

The ZRW153 Wall Mounted 3-Way Switch is a component of the HomePro lighting control system. Wire the Wall
Mounted Switch in place of the standard wall switch according to the diagram above and program from the Wireless
Controller to operate loads. Inclusion of this Switch on the ZTH100 Wireless Controller menu allows remote ON/OFF
control of lamps connected.
This Wall Mounted Switch is designed to work with other Z-Wave enabled devices. Z-Wave nodes of other types can
be added to the system and will also act as repeaters if they support this function of repeating the signal received to
other modules in the system.
As part of a Z-Wave network, the ZRW153 will also act as a wireless repeater to insure that commands intended for
another device in the network are received. This is useful when the device would otherwise be out of the radio range
of the wireless controller.
There are no field repairable assemblies on this unit.. If service is needed, the unit must be returned where purchased.
DANGER! SHOCK HAZARD. Read and understand these instructions before installing. This device is intended for
installation in accordance with the National Electric code and local regulations in the United States, or the Canadian
Electrical Code and local regulations in Canada. It is recommended that a qualified electrician perform this installation.
Make sure the load controlled the switch does not exceed 1800 watts. For indoor use only. Retain instructions for
future use.

INSTALLATION

With power off, wire this switch in place of a current wall switch according to the diagram above.
AS101’s are required to be wired to the same line (or neutral) which is also wired to the master unit as well as the
load being controlled, and not wired to any other neutral. If multiple neutrals are tied together in one box, separate
the neutrals to preserve the integrity of the ZRW153 circuit. Caution! Do not wire unit “live” (with power on the circuit)
and do not allow the yellow wire to contact line voltage, neutral or ground or you will damage the device.
See the ZTH100 Wireless Controller operating instructions to add this module under the command of the Wireless
Controller.

Shown with supplied

Decora

TM

trim plate

Note: This module must be “Included in the
Network” only where it will be permanently
installed
. The proper operation of this node in the
mesh network is dependent on it knowing its
location with respect to other nodes. You cannot
“test bench” configure this module.