Requirements

To begin, make sure you have the following equipment: A compatible Bimba AC stepper motor.

A small flat blade screwdriver for tightening the connectors (Bimba screwdriver included).

A personal computer running Microsoft Windows 98, NT, Me, 2000, XP, Vista, 7, or 8 (32 bit or 64 bit).

IQ

®

Stepper software, available at www.bimba.com.

For programmable models, IQ

®

Programmer software (available at www.bimba.com).

A CAT5 network cable (not included).

For more detailed information, please download and read the Bimba STP-AC5 Hardware Manual, available at www.bimba.com.

Step 1

a)

Download and install the IQ

®

Stepper software.

b)

Launch the software by clicking:

Start / All Programs / Bimba / IQ

®

Stepper

c)

Connect the drive to your network or PC using a standard CAT5 cable.

d)

Select an appropriate IP address using the rotary switch on the STP-AC5. For more

information about network configurations and IP addressing, please consult the

STP-AC5 Hardware Manual.

Step 2

a)

Wire the drive to the AC power source.

(do not apply power until all connections to the drive have been made)

Note, the STP-AC5-*-1 accepts AC voltages from 108-132 VAC,

while the STP-AC5-*-2 accepts AC voltages from 108-250 VAC.

The STP-AC5-*-1 contains an internal 8A fast acting fuse. The STP-AC5-*-2 contains an internal 3.5A fast acting fuse. If

an external fuse is desired, we recommend a 6A fast acting fuse for the 120V STP-AC5 and a 3 amp fast acting fuse for

the 220V version.

4

3

21

0 F

E D C B A

9 8

76

5

To Line (Hot)

To Neutral