9. TROUBLE-SHOOTING:

Symptoms

Possible causes/counter-measures

No image

1. Power cord is not properly connected.

2. Cables are not properly connected.

3. Power switch is not turned on.

4. The built-in fuse is broken: Change fuse.

5. Change the output resolution.

Image bending

1. Camera not in right position, adjust the camera.

2. Distortion of LCD display, press the “Auto adjust” of the

LCD.

Out of focus or blurring

image

1. The object is too close to the lens.

2. Focus is on the top point of zoom, press ZOOM-.

3. Auto-focus is not on: press AUTO again.

4. Fog on the lens in damp climate. It will disappear

gradually when the equipment warms up.

If the problem still remains after checking the above, consult your dealer or authorized service

personally.

10. PACKING LIST

Item

Quantity

Power cord

1

Power adaptor(12V/2A)

1

VGA cable

1

Switch cable(RCA to mini

)

1

USB cable(2.0)

1

Remote control

1

User manual(CD)

1