Technical data delhi 114 – Hase Delhi User Manual

Page 45

Advertising
background image

45

min. 20*

23

Ш 25

7

Ш 45

Ш 39

10. Technical Data Delhi 114

The Delhi 114, certified in compliance with DIN-EN 13240 and Art. 15 a B-VG (Aus-
tria)
, can only be operated when the fire box is closed; more than one device can be
connected to the chimney.
VKF-No.: 23311

The following data applies to the chimney characteristics in accordance with EN
13384-1 /-2

Combustion Values

Wood

Nominal Thermal Output

5

kW

Efficiency

82

%

Particulate

16

mg/m³

CO content at 13% O2

1021

mg/m³

Waste Gas Mass Flow Rate

4,5

g/s

Waste Gas Outlet Temp.

315

˚C

Min. Supply Pressure at Nominal Thermal Output

12

Pa

Depending on the insulation of the building, the nominal thermal output of 5 kW indi-
cated on 15 - 60 m² (subject to change).

Dimensions:

Height Width Depth

Stove

113,5 cm

45 cm

45 cm

Fire box

44 cm

29 cm

28 cm

Weight

118 kg

* Vertical flue pipe length

min. 20 cm

Flue pipe diameter

15 cm

Pipe diameter of Hase ventilation system**

10 cm

* For separate air supply in low-energy houses and insufficient combustion air supply
in the room where the stove is installed

Front view

Side view

Top view

Dimensions in cm

Height for top installation: 112

Stove

height:

113,5

Connection area for the
inst. of Hase air system
below

Height for the inst. of Hase air system: 18

Advertising