4. DETAILED OPERATING INSTRUCTIONS

28

40 ampere-hours of

26

capacity delivered at

this point

24

22

20

Minimum cutoff voltage (18 volts)

18

16

0 10 20 30 40 50 60 70 80

Discharge time (minutes)

Figure 4-1. Typical discharge curve for 40 ampere-hour

lead-acid aircraft battery



Figure 4-2 illustrates discharge curves for typical SLABs at different discharge rates.
Note that the cell voltage drops much more rapidly at the higher discharge rates, i.e. the
rates at which a greater current is drawn during a shorter period of time.

25.0

12

24.0

20-hour rate

23.0

22.0

21.0

8-hour rate

15-hour rate

12-hour rate

20.0

4-hour rate

2-hour rate

19.0

1-hour rate

18.0

0 2 4 6 8 10 12 14 16 18 20

Discharge time (hours)

Figure 4-2. Typical discharge curves for SLABs at different rates