4. DETAILED OPERATING INSTRUCTIONS




1-hour rating

Discharge settings

Ampere

Time Rate Cutoff

Volts hours (min) (amperes) (volts)

24 10 60

8 18/20

24

15 60 12 18/20

24

20 60 16 18/20

24

30 60 24 18/20

24

40 60 32 18/20

12 10 60

8

9/10

12

15 60 12 9/10

12

20 60 16 9/10

12

30 60 24 9/10

12

40 60 32 9/10

Table 4-2. Discharge test setting for sealed lead-acid batteries



4.5.2 NICKEL-CADMIUM BATTERIES
For nickel-cadmium batteries the cutoff voltage should equate to an average of 1 volt per
cell, when discharge tested at a current of approximately 80% of the C

1

-rate. For a 24

volt/10 ampere-hour battery with 19 cells, the cutoff voltage would be set to 19 volts when
discharging at 8 amperes (see table 4-3).

1-hour rating

Discharge settings

Ampere

Time Rate Cutoff

Volts hours (min) (amperes) (volts)

24 10 60

8

19

24

15 60 12 19

24

20 60 16 19

24

30 60 24 19

24

40 60 32 19

12 10 60

8

10

12

15 60 12 10

12

20 60 16 10

12

30 60 24 10

12

40 60 32 10

Table 4-3. Discharge test setting for nickel-cadmium batteries



4.5.3 SETTING CUTOFF VOLTAGE ON THE BETA D-50
Before setting the cutoff voltage, a battery has to be connected and the unit has to be