3.2.3 Programming for Call-up Operation

This feature is only used when the telephone entry system is interfaced with a DoorKing 1816
Telephone Intercom system under certain special applications. The factory setting for this feature is
OFF. Do not change this feature to ON. Refer to the 1816 Installation Manual, and check with your
DoorKing representative on the special applications that this feature is used for.
Factory Setting = OFF

1.

Press *78 and enter the four-digit MASTER CODE _ _ _ _ (beep).

2.

Enter 0* (beep) to turn the call up feature OFF.
Enter 1* (beep) to turn call up ON.

3.

Press 0# TOGETHER to end this programming step (beeeeeep).


3.2.4 PC Programming Table

The information in the chart will be required when you program the PC programmable telephone entry
system from your PC. The chart is provided for you to record the information that has been
programmed in the preceding steps.

Control Board

Series

Master Code

(enter number)

Memory Size

(circle one)

Memory Chip

(circle one)

Single / Multiple

(circle one)

40E

(enhanced)

25 75 125 250
500 1000 2000

3000

MemPLUS

STANDARD

SINGLE

MULTIPLE

STOP!!


If the telephone entry system is to be programmed from a PC, no other programming is required at
the system itself. Complete the chart in section 3.2.4 as this information will be required when
programming the unit from your computer. Refer to the Remote Account Manager for Windows
software manual for additional programming information. Continue with the remaining sections in this
chapter if the telephone entry system will be programmed by any other method. If the factory setting
matches your need, there is no reason to reprogram that section.

Remember that relay hold open time zones, security levels, and elevator control functions can only be
programmed from the Remote Account Manager software. If any of these features are being used,
do not proceed with any other programming steps in this manual.

33