Wunder Audio CM67 User Manual

Wunder Audio Microphones

Advertising
background image

1. CM67

The Wunder Audio CM67 Tube Microphone is targeted to the
professional with the most demanding criteria. These boutique
microphones are hand assembled in Texas per customers order.
Tubes are hand tested NOS EF86.

How to replace the vacuum tube

Disconnect microphone from PSU.

Remove the three nickel screws at the lower end of the microphone
grille housing.

The Grille can be pulled off in upwards direction.

Next remove the small screw that is located several inches below
the Wunder Audio diamond badge.

The Complete body shell can now be pulled off in an upwards
direction.

The vacuum tube can now be removed by wiggling the tube with a
downward motion taking care to clear the large black transformer
below it.

Insertion of a new tube should be done in reverse order
of the description above.

How to change the polar pattern.

Locate the pattern switch on the PSU. Use this switch to operate the
Directional Characteristics: Omni-, cardioid-, figure-eight, and eight
intermediate positions. The center position is the Cardioid setting.

As you turn from position to position it will take a few seconds for the
polarization voltage to settle and achieve the desired polar pattern.