CAUTION

FIG. 3-8 (ProMax)

Attachments at

po

.

Make wire attachments at STB

s.

Splitting and stripping wire ends to be

connected as shown

(Fig. 3-6)

.

Loosen terminal screws.

Insert wire under flat plate and tighten screw. It

does not matter which wire, white or striped,

goes on which terminal

(Fig. 3-7)

.

Make wire attachments at power head.

oMax

. STB

s are connected to terminals

#2 and #3 on power head

(Fig. 3-8)

.

. STB

s are connected to

terminals #3 and #4 on power head

(Fig. 3-8)

.

4. Check the following

.

Insure that no part of door or its hardware is in

path between lenses of

source

and

sensor

.

Insure that tops of lenses are between 5

-6

above the floor

(Fig. 3-9)

.The brackets are

flexible and can be adjusted slightly if needed.

NOTE: STB alignment check must be performed
following connection to electrical power (see page 21).
DO NOT PLUG IN YET!

Staples whic
to stop wor

When using the insulated

staples,

ou fasten them only as tightly

ugly.

FIG. 3-7

Attachments

at STB.

FIG. 3-9 Check lens height

.

top edge of lens between

5

- 6

above floor.

FIG. 3-6

Splitting and

2

3

FIG. 3-8 (Stealth)

Attachments at

po

.

3

4

19

STB

SELF-DIAGNOSTIC TROUBLESHOOTING

ON

ON

NORMAL OPERATION

NONE REQUIRED

OFF

OFF

1.POWER HEAD NOT POWERED
2.WIRING FROM POWER HEAD BAD

1.CHECK BREAKERS, FUSES, PLUGS
2.CHECK WIRING FOR OBVIOUS SHORTS

OFF

ON

1.WIRING TO SOURCE MISSING OR BAD
2.POWER HAS BEEN INTERRUPTED

1.CHECK WIRING
2.REMOVE POWER AND REAPPLY

2 BLINKS

, PAUSE (REPEAT)

ON

1.BEAM NOT ALIGNED 2. BEAM OBSTRUCTED
3.SENSOR DEFECTIVE

1.CHECK ALIGNMENT 2. CHECK FOR OBSTRUCTION
3.CALL CUSTOMER SERVICE

1.WIRE TO SENSOR MISSING OR BAD
2.SENSOR DEFECTIVE

1.CHECK WIRING
2.CALL CUSTOMER SERVICE

OFF

ON

1.SENSOR RECEIVING INTERFERENCE

1.ATTEMPT TO DETERMINE SOURCE OF INTERFERENCE
2.CALL CUSTOMER SERVICE

ON

1.SOURCE NOT SENDING PULSES
2.SOURCE DEFECTIVE

1.CALL CUSTOMER SERVICE
2.CALL CUSTOMER SERVICE

NOTE

: IF OPERATING PROBLEM EXISTS, THE DOOR CAN BE CLOSED IF YOU:

1

. DISCONNECT THE STB SYSTEM FROM THE OPERATOR AND

2

. HOLD WALL CONTROL BUTTON

DOWN UNTIL DOOR IS CLOSED. (REMOTE CONTROL & WIRELESS KEYPAD WILL NOT WORK WITHOUT STB)

SOURCE (RED LED) SENSOR (GREEN LED) INDICATED CONDITION

REQUIRED ACTION

2 BLINKS

, PAUSE (REPEAT)

3 BLINKS

, PAUSE (REPEAT)

4 BLINKS

, PAUSE (REPEAT)

CUSSTOMMEER SERRVIICCEE:: 1..8000.3544.336433 or wwww.ggeenniieccommpaanyy.ccom

Safe-T-Beam

®

Alignment Check

After turning the electrical power on, if the
STB’s are not in proper alignment, the red
LED (Source) will blink continuously.

To correct the problem – the brackets are
flexible and can be adjusted slightly to bring
the system into alignment.
When the STB’s are in alignment the red LED
will stop blinking and stay on.

Advertising