Table 12. DC Voltage, Resistance, and Conductance Function Specifications

Accuracy

Function Range

Resolution

Model 83

Model 87

L

6.000 V
60.00 V
600.0 V
1000 V

0.001 V
0.01 V
0.1 V
1 V

±

(0.1 % + 1)

±

(0.1 % + 1)

±

(0.1 % + 1)

±

(0.1 % + 1)

±

(0.05 % + 1)

±

(0.05 % + 1)

±

(0.05 % + 1)

±

(0.05 % + 1)

F

mV

600.0 mV

0.1 mV

±

(0.3 % + 1)

±

(0.1 % + 1)

e

nS

600.0

Ω

6.000 k

Ω

60.00 k

Ω

600.0 k

Ω

6.000 M

Ω

50.00 M

Ω

60.00 nS

0.1

Ω

0.001 k

Ω

0.01 k

Ω

0.1 k

Ω

0.001 M

Ω

0.01 M

Ω

0.01 nS

±

(0.4 % + 2)

1

±

(0.4 % + 1)

±

(0.4 % + 1)

±

(0.7 % + 1)

±

(0.7 % + 1)

±

(1.0 % + 3)

2

±

(1.0 % + 10)

1

±

(0.2 % + 2)

1

±

(0.2 % + 1)

±

(0.2 % + 1)

±

(0.6 % + 1)

±

(0.6 % + 1)

±

(1.0 % + 3)

2

±

(1.0 % + 10)

1

1.

When using the REL

Δ

function to compensate for offsets.

2.

Add 0.5 % of reading when measuring above 30 M

Ω

in the 50 M

Ω

range, and 20 counts below 33 nS in the 60 nS range.