Using the input terminals – Fluke 189 User Manual

Page 31

Advertising
background image

Getting Acquainted

Using the Input Terminals

2

2-17

Using the Input Terminals

All functions except current use the

*

and

COM

inputs. Current functions use the inputs shown

below:

I

or

K

function:

Use A and COM inputs from 400

mA to 20 A. Use mA/

µ

A and COM for inputs

400

mA.

=

or

x

function: Use mA/

µ

A and COM for inputs

5000.0

µ

A.

If a test lead is plugged into the mA/

µ

A or A terminal, but

the rotary switch is not correctly set to one of the current
measuring positions, the Input Alert™ beeper warns you
by making a chirping sound and the primary display shows
"

LEAd5

". This warning is intended to stop you from

attempting to measure voltage, continuity, resistance,
capacitance, or diode values when the leads are plugged
into a current terminal.

Figure 2-5 shows the input terminals.

A

mA

COM

V

A

tc014f.eps

Figure 2-5. Input Terminals