ID Scan :
If a TGID matches a TGID stored in an unlocked channel, the scanner goes to the V-Ch and monitors the
transmission until it ends.

While monitoring a TGID already stored into the Memory, the first line of the display alternates between
the current site name and current channel group name every 1 second, and second line displays the
current channel name. The Quick Key numbers for the current site and group blinks.

While monitoring a TGID not stored into the Memory, the first line displays current site name, and the
second line displays the current TGID. The current Site and Group Quick Keys blink.

While monitoring the TGID:
Press [Scan / srch] or turn [Scroll Control] to return to the C-Ch. Then the scanner waits for a moment on
the C-Ch to see if another TGID is active. If the scanner finds another TGID, it monitors the found TGID. But
if there is only the TGID that was being monitored just before, it monitors that TGID again.

Press [L/O] to lock out the TGID and store it to the list of ID Lockouts of the system (See: Clr All L/O IDs).
This lock out information is common to every site in the system. Then the scanner returns to the C-Ch.

If the transmission ends, it returns to the C-Ch and exclusively listens for the last-active TGID until the site
delay time expires.

After the system delay time elapses, the scanner checks to see if the Site Hold time has elapsed. If so, the
scanner advances to the next System or Site. If the Site Hold Time has not elapsed, the scanner continues
to monitor the C-Ch for TGID activity.

Lockout Operation
You can lock out each site but cannot lock out the system to which the site belongs.

In Trunked Systems (except EDACS SCAT system), one system can have multiple sites and those sites share
the same TalkGroup IDs.

If you lock out a TGID, the TGID is locked out for all sites in the system.