Uniden BCD396XT User Manual

Page 233

Advertising
background image

233

<COMMAND BSV >
Get/Set Battery Info
Controller → Radio
BSV [\r]
BSV,[BAT_SAVE],[CHARGE_TIME][\r]

Radio → Controller
BSV, [BAT_SAVE],[CHARGE_TIME] [\r]
BSV,OK[\r]

[BAT_SAVE]

Battery Save

(0:OFF / 1:ON)

[CHARGE_TIME]

Battery Charge Time (1-16)



< COMMAND COM >
Get/Set COM port setting
Controller → Radio
COM,[/r]
COM,[BAUDRATE],[RSV][/r]

Radio → Controller
COM,[BAUDRATE],[RSV][/r]
COM,OK[/r]

[BAUDRATE] :

OFF

:OFF

4800 :4800bps

9600 :9600bps

19200 :19200bps

38400 :38400bps

57600 :57600bps

115200:115200b

Note:
When receive “COM,OK”, next command should not be send in 2 second.
Only PC Control (Baud Rate) does not become an initial-setting value.
<COMMAND CLR>
Clear All Memory
Controller → Radio
CLR[\r]
Radio → Controller
CLR,OK[\r]

All the memories are set for initial setting.
This command is only acceptable in Programming Mode.

Note :
It takes dozens of seconds.
Only PC Control (Baud Rate) does not become an initial-setting value.

Advertising