Uniden BCD396XT User Manual

Page 239

Advertising
background image

239

<COMMAND TRN>
Get/Set Trunk Info
Controller → Radio
TRN,[INDEX][\r]
TRN,[INDEX],[ID_SEARCH],[S_BIT],[END_CODE],[AFS],[RSV],[RSV],[EMG],[EMGL],
[FMAP],[CTM_FMAP],[RSV],[RSV],[RSV],[RSV],[RSV],[RSV],[RSV],[RSV],[RSV],[RSV]
,
[MOT_ID],[EMG_COLOR],[EMG_PATTERN],[P25NAC],[PRI_ID_SCAN][\r]
Radio → Controller
TRN,[ID_SEARCH],[S_BIT],[END_CODE],[AFS],[RSV],[RSV],[EMG],[EMGL],[FMAP],
[CTM_FMAP],[RSV],[RSV],[RSV],[RSV],[RSV],[RSV],[RSV],[RSV],[RSV],[RSV],
[TGID_GRP_HEAD],[TGID_GRP_TAIL],[ID_LOUT_GRP_HEAD],[ID_LOUT_GRP_TAIL],
[MOT_ID],[EMG_COLOR],[EMG_PATTERN],[P25NAC],[PRI_ID_SCAN][\r]
TRN,OK[\r]

[INDEX]

: System Index

[ID_SEARCH] : ID Search/Scan (0:ID Scan mode / 1: Search Mode)

[S_BIT]

: Motorola Status Bit

(0:Ignore, 1:Yes)

[END_CODE] : Motorola End Code(0:Ignore,1:Analog,2:Analog and Digital)

[AFS]

: EDACS ID Format

(0:Decimal / 1:AFS)

[EMG]

: Emergency Alert

(0:Ignore / 1-9:Alert)

[EMGL]

: Emergency Alert Level (0:OFF / 1 - 15)

[FMAP]

: Fleet Map

(0-16, 0-15:Preset, 16:Custom)

[CTM_FMAP] : Custom Fleet Map Setting (######## : # is 0-E)

# means Size Code of each BLOCK (from 0 to 7)
0 : Size Code 0

5 : Size Code 5

A : Size Code 10

1 : Size Code 1

6 : Size Code 6

B : Size Code 11

2 : Size Code 2

7 : Size Code 7

C : Size Code 12

3 : Size Code 3

8 : Size Code 8

D : Size Code 13

4 : Size Code 4

9 : Size Code 9

E : Size Code 14

[TGID_GRP_HEAD]

: TGID Index Head of the System

[TGID_GRP_TAIL]

: TGID Index Tail of the System

[ID_LOUT_GRP_HEAD]: L/O TGID Group Index Head of the System

[ID_LOUT_GRP_TAIL]: L/O TGID Group Index Tail of the System
[MOT_ID]

: Motorola/P25 ID Format

(0:Decimal / 1:HEX )

[EMG_COLOR]

: Emergency Alert Light color
(OFF,BLUE,RED,MAGENTA,GREEN,CYAN,YELLOW,WHITE)

[EMG_PATTERN]

: Emergency Alert Light Pattern(0:ON/1:SLow /2:Fast)

[P25NAC]

: P25 NAC Status (0-FFF:0-FFF/SRCH:Nac Search)

[PRI_ID_SCAN] : Priority ID Scan ( 0:OFF / 1: ON)
[RSV]

: Reserve Parameter

* This is always only “,”.


Get/Sets Trunked System Information.
The scanner returns only "," to punctuate for parameters which are not
appropriate the system type.
In set command, the scanner neglects the parameters that are not appropriate
the system.
In set command, only "," parameters are not changed.
The set command is aborted if any format error is detected.
When the system protect bit is ON, except [TGID_GRP_HEAD], [TGID_GRP_TAIL],
[ID_LOUT_GRP_HEAD], [ID_LOUT_GRP_TAIL], other parameters will be send as a
reserve parameter in the Radio -> Controller command.
This command is only acceptable in Programming Mode.

Advertising