<COMMAND ABP>
Get/Set APCO-P25 Band Plan
Controller → Radio
① ABP,[INDEX][\r]

ABP,[INDEX],[BASE_FREQ_0],[SPACING_FREQ_0],[BASE_FREQ_1],[SPACING_FREQ_1], .
. .
[BASE_FREQ_E],[SPACING_FREQ_E],[BASE_FREQ_F],[SPACING_FREQ_F][\r]
Radio → Controller
① ABP,[BASE_FREQ_0],[SPACING_FREQ_0],[BASE_FREQ_1],[SPACING_FREQ_1], . .
.
[BASE_FREQ_E],[SPACING_FREQ_E],[BASE_FREQ_F],[SPACING_FREQ_F][\r]
② ABP,OK[\r]


[INDEX]

: Site Index

[BASE_FREQ_n]

: Base frequency (MHz)(25.0000MHz to 1300.0000MHz,
5.0Hz step)

Base_FREQ_n = (base frequency * 10^6) / 5
(Hexadecimal number)

[SPACING_FREQ_n] : Spacing frequency(kHz)(0.125kHz to 128.0kHz,

0.125kHz step)

SPACING_FREQ_n = (spacing frequency *10^3)/125
(Hexadecimal number)
*n : Base Plan number

EX.) Base frequency = 851.00625MHz, Spacing frequency = 6.25kHz

[BASE_FREQ_n] = (851.00625*10^6)/5 = A2510A2(H)

[SPACING_FREQ_n] = (6.25*10^3)/125= 32 (H)


Band Plan that has no data returns “0”.

When the system protect bit is ON, all the parameters will be send as a
reserve parameter in the Radio -> Controller command.
This command is only acceptable in Programming Mode.