Artel DLM205 User Manual

Artel ships the dlm205 configured as follows, Sw1 configuration switch functions

Advertising
background image

QUICK START GUIDE

www.artel.com | 978-263-5775 | [email protected] | [email protected]

Artel ships the DLM205 configured as follows:

DigiLink Manager enabled for use in DL4000 chassis

Refer to the DLC205/DLM205 Function Module Installation and Operations Manual for

additional configuration and default settings.

SW1 Configuration Switch Functions

ON - Manager function is on and allowed to manage a DL4000 chassis. This mode is

only available in a DL4000 chassis and only when no other manager is present.

OFF - Manager function is disabled allowing only Ethernet functions. This mode is

available in any chassis.
Note: The EMS LED will remain red if the configuration switch is ON and there is a

manager conflict.

SW1

FRONT PANEL RESET SWITCH CONFIGURATION

Function

Action

EMS LEDs

Description

Restart the EMS Press and

Release

n

Red

EMS is restarted, LED goes off when done.

Reset the EMS

Hold for greater
than 8 seconds

n

Red then

n

Yellow

EMS and all VLAN parameters are reset to
factory default including changing the IP
address to 192.168.100.5.

Reset Switch Functions

Gig-E Aggregator and Optical Transceiver with

On-Board Chassis Management [DLM205]

Note: Refer to the DLC205/DLM205 Function
Module Installation and Operations Manual
for
additional configuration and default settings.