Crydom RHP Series User Manual

3 phase rhp - hybrid solid state contactors, 3 phase contactor, Dc input

Advertising
background image

3 Phase RHP - Hybrid Solid State Contactors

Part Number Nomenclature

D5

40

12

RHP

3

Nominal Coil

/Control Voltage

D5: 5 VDC

D12: 12 VDC
D24: 24 VDC

E: 24 VAC

F: 120 VAC

G: 220 VAC

Operating
Voltage VAC
50/60 Hz

12: 120 V 1-phase
24: 240 V 3-phase
or 1-phase

28: 280 V 3-phase
60: 600 V 3-phase

Three
Phase
Device

Load Current
40
: 40 Amps
50: 50 Amps

SERIES

Derating Curves

3RHPXX

40

XX

25

35

45

55

65

75

Ambient Temperature, °C

20

25

30

35

40

45

Load Current, Amps rms

AWG # 6
AWG # 8

Power lead size

3RHPXX

50

XX

25

35

45

55

65

75

Ambient Temperature, °C

20

25

30

35

40

45

50

55

Load Current, Amps rms

AWG # 6
AWG # 8

Power lead size

Safe Operating Area

Safe Operating Area

3 Phase Contactor

DC Input

40-50 Amp
120/240 VAC

Combined SSR and EMR advantages
Lifetime >2 million operations @ full load
No heat sink required
DC logic compatible input
Input status LED indicator
Wire, lug or quick connect termination
DP contactor footprint
CE compliant & UL/cUL recognized
100k-cycle UL508 endurance rating

3 Phase Contactor

AC Input

40-50 Amp
280/600 VAC

Combined SSR and EMR advantages
Lifetime >2 million operations @ full load
No heat sink required
Input status LED indicator
Wire, lug or quick connect termination
DP contactor footprint
CE compliant & UL/cUL recognized
100k-cycle UL508 endurance rating

CONTROL SPECIFICATIONS

Coil Voltage Range

Coil Power Consumption, Inrush
Coil Power Consumption, Sealed

Control Voltage Suffix

Voltage suffix
Operating Voltage (50/60Hz)

Maximum Off-State Leakage Current per channel

Load Current suffix

Maximum Load Current per Phase @ 40°C

Power terminals / wire range

28

24 - 280 VAC

0.05 mA @ 240 VAC

40

40 A Resistive

Dual quick connect and Binder

head screws / AWG#14 - AWG#8

Input to Output Dielectric Isolation.

Input/Output to Ground Dielectric Isolation.

Contacts (Double Break )

Ambient Operating Temperature Range

Ambient Storage Temperature Range

Maximum Number of Operations per Minute

Lifetime @ Rated Load Current, 40°C ambient
temp, 30 operations/min, Rated Vcontrol

Weight (typical)

See Derating Curves for additional operational conditions.
The RHP includes a Solid-State Relay. Therefore, the output is never completely open.
The RHP includes an overtemperature protection for the Solid-State Module.

GENERAL SPECIFICATIONS

540 grs (1.19 lb)

2500 VAC

-20°C to 75°C

4000 VAC

Three Normally Open

30 operations per min

> 2 Million operations

-40°C to 100°C

OUTPUT SPECIFICATIONS

Dual quick connect and Box

lugs / AWG#14 - AWG#6

Screw torque requirements

18 in lbs (2.1 Nm)

25 in lbs (2.9 Nm)

60

48 - 600 VAC

0.06 mA @ 480 VAC

50

50 A Resistive

2

3

3

1

1

1

4

2

Specificationts @ 25°C unless otherwise noted.

1

3

4

Min. Turn-On Voltage

Min. Turn-Off Voltage

E

20 - 26 VAC, 50/60 Hz

56 VA @ 24 VAC

6.6 VA @ 24 VAC

Coil Terminals

10 in lb (1.13 Nm)

10 in lb (1.13 Nm)

10 in lb (1.13 Nm)

Input Connector

5.31 in lb (0.6 Nm)

5.31 in lb (0.6 Nm)

5.31 in lb (0.6 Nm)

20 VAC

12 VAC

F

100 - 130 VAC, 50/60 Hz

56 VA @ 120 VAC

6.6 VA @ 120 VAC

100 VAC

24 VAC

G

208 - 240 VAC, 50/60 Hz

56 VA @ 220 VAC

6.6 VA @ 220 VAC

208 VAC

48 VAC

Max. Turn-On Time

Max. Turn-Off Time

16.6 mS @ 60 Hz / 20 mS @ 50 Hz

32 mS @ 60 Hz / 40 mS @ 50 Hz

CONTROL SPECIFICATIONS

Control Voltage Range

Control Voltage Suffix

Max. Reverse Voltage

Min. Turn-On Voltage

Min. Turn-Off Voltage
Input Current

D5

4.5 - 5.5 VDC

-5.5 VDC

4.5 VDC

1 VDC

12mA @ 5 VDC

D12

10 - 15 VDC

-15.5 VDC

9.5 VDC

2 VDC

12mA @ 12 VDC

D24

22 - 27 VDC

-27.5 VDC

9.5 VDC

2 VDC

12mA @ 24 VDC

Voltage suffix

Operating Voltage (50/60Hz)

Maximum Off-State Leakage Current per channel

Load Current suffix

Maximum Load Current per Phase @ 40°C

Power terminals / wire range

Input to Output Dielectric Isolation

Input/Output to Ground Dielectric Isolation

Contacts (Double Break)

Ambient Operating Temperature Range

Ambient Storage Temperature Range

Maximum Number of Operations per Minute

Lifetime @ Rated Load Current, 40°C ambient
temp, 30 operations/min, Rated Vcontrol

Weight (typical)

OUTPUT SPECIFICATIONS

12

100 - 120 VAC

40

40 A Resistive

Dual quick connect and Binder

head screws / AWG#14 - AWG#8

0.05 mA @ 120 VAC

Three Normally Open

30 operations per min

> 2 Million operations

-40°C to 100°C

4000 VAC

GENERAL SPECIFICATIONS

24

208 - 240 VAC

0.06 mA @ 240 VAC

50

50 A Resistive

Dual quick connect and Box

lugs / AWG#14 - AWG#6

540 grs (1.19 lb)

2500 VAC

-20°C to 75°C

2

3

3

4

Max. Turn-On Time

Max. Turn-Off Time

16.6 mS @ 60 Hz / 20 mS @ 50 Hz

32 mS @ 60 Hz / 40 mS @ 50 Hz

Screw torque requirements

18 in lbs (2.1 Nm)

25 in lbs (2.9 Nm)

See Derating Curves for additional operational conditions.
The RHP includes a Solid-State Relay. Therefore, the output is never completely open.
The RHP includes an overtemperature protection for the Solid-State Module.

1

1

1

2

Specificationts @ 25°C unless otherwise noted.

1

3

4

PATENT

PENDIN

G

PATENT

PENDIN

G