Wiring for a Single Unit – Telephone Mode

DOORKING

1875-010

GND

ENTRY

BY-PASS

1

2

3

4

5

6

7

8

C.O.

PH IN

PH OUT

HOME

16.5 VAC

20 VA

Mag Lock

Power

DOORKING, INC., INGLEWOOD, CA 90301

Date:

Dwg. No.

Rev.

Title:

6/09

B

M1812P-001

1812 Plus – single system.
Basic wire connections.

2

Magnetic locks or electric strikes must be powered from a separate UL Listed power
transformer. Do not power strikes or magnetic locks from the 1812 power transformer.

3

Mount the by-pass switch in a location that is easily accessible by the homeowner. The By-
Pass switch IS NOT optional – it must be installed as part of the 1812 system.
If
installed outdoors, be sure to protect the by-pass switch from direct exposure to rain, snow
and other elements.

1

2

1

7

3

5

4

7

6

6

A

Locate the telephone company demarcation device.
IMPORTANT! Identify the wires that connect to the
homeowner’s telephones
. Disconnect these wires from
the demarcation device and connect them to terminals 7
and 8 on the by-pass switch.

Connect a twisted-pair telephone wire to terminals 1 and 2
on the by-pass switch. Connect the other end of these
wires to the telephone company demarcation device where
you removed the wires from above.

Place the by-pass switch in the “BY-PASS” position until
the 1812 unit is installed. Test the homeowner’s telephone.
They should have dial tone while the switch is in the BY-
PASS position.

Use supplied 16.5 VAC, 20 VA power transformer or UL Listed equivalent. DO NOT
Power this device with a 24 Volt transformer or source voltage.

Use only twisted pair telephone wire that is rated for direct underground burial. DO NOT use
wire that is intended for indoor applications . Recommend Cat5e Gel Filled (flooded)
UV Resistant Direct Burial Cable in conduit. DO NOT run telephone wires and high
voltage wires in the same conduit.
Check the phone wire chart for wire size / distance.

Check for polarity on the phone "IN" wires, terminals 1 and 2. Terminal 2 must be positive
with respect to terminal 1. Set a VOM meter to measure DC volts. Place the positive lead on
terminal 2 and the negative lead on terminal 1. If the meter shows a positive voltage - OK. If
the meter shows a negative voltage (needle moves off scale to the left), reverse the wires on
terminals 1 and 2.

4

5

6

7

Use minimum 18 AWG wire for runs up to 100 feet; 16 AWG wire for runs up to 200 feet. It is
recommended to keep power wire runs as short as possible. Check the power wire chart for
wire size / distance.

Be sure to properly ground all devices. Minimum 12 AWG wire.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

Mic
Vol

Master

Code

1 2 3 4 5 6 7 8 9 1011

Speaker

Vol

Keypad

A

By-Pass

Switch

7

B

B

Optional DoorKing Surge Suppresser P/N 1877-010 (or
equivalent) highly recommended.

For best protection, surge suppresser ground wire must be
3-ft. or less in length. Use minimum 12 AWG wire.

Ring is Positive with respect to Tip terminal. See

3

This device is powered by a 16.5 VAC
transformer. DO NOT power this device with a
24 VAC transformer or power source.

C

C

Maintain polarity!

PH IN #3 connects to Term 1.

PH IN #4 connects to Term 2.

PH OUT #5 connects to Term 5.

PH OUT #6 connects to Term 4.

3

Ri

n

g

Ti

p

Ri

n

g

Ti

p

Gnd

Gnd

Blue/

W

hi

te (

-)

W

h

it

e/

B

lue

(+

)

House Phones

Phone

Jack

Phone

Jack

Phone

Jack

From Phone

Company

Blue/White

Orange/White

White/Orange

White/Blue

Blue/White

White/Blue

Vehicular Gate

Operator

Pedestrian

Gate / Door

W

h

it

e/

B

lue

(+

)

Blue/

W

hi

te (

-)