2 system parameter programming, 1 phone / intercom mode, 2 single or multiple systems – DoorKing 1812 Plus User Manual

Page 24: 3 system attention number, 4 single or double ring

Advertising
background image

2.2 System

Parameter

Programming

2.2.1 Phone / Intercom Mode

Default setting is 1 (Phone Mode).

The 1812 is normally connected in series with a resident’s incoming phone line, which supplies a
constant source of DC voltage. When the 1812 is connected in this manner, program the unit for
PHONE mode.

If the 1812 is to be connected to an open C.O. (Central Office) port on a key type telephone system,
or if the 1812 is connected directly to a telephone without a C.O. line, program the unit for
INTERCOM mode. When programmed in intercom mode, the 1812 will supply the constant DC
voltage necessary for operation and will disconnect the PH-IN terminals from the circuit since these
are not used in intercom mode.

If the 1812 is programmed for the intercom mode, the call forwarding and preprogrammed dial-out
phone number features will not work.

1. Press * 0 6 and enter the MASTER CODE. [ * 0 6 _ _ _ _ (beep)]

2. Press 1 * for phone mode, OR press 0 * for intercom mode. [ _ * (beep)]

3. Press 0# TOGETHER to end. [0# (beeeeeep)]

2.2.2 Single or Multiple Systems

Default setting is 1 (Single System).

Set for single if the 1812 is the only unit connected to the phone line, or set to multiple if more than
one 1812 is connected to the phone line.

1. Press * 6 1 and then enter the MASTER CODE. [ * 6 1 _ _ _ _ (beep)]

2. Press 1 * for a single system OR press 0 * for multiple systems. [ _ * (beep)]

3. Press 0# TOGETHER to end. [0# (beeeeeep)]

2.2.3 System Attention Number

Default setting is 7.

The system attention number is the number that the 1812 responds to when called from the
residence. If more than one 1812 is sharing the phone line, be sure the attention number to each unit
is programmed with a unique attention number.

1. Press * 6 2 and then enter the MASTER CODE. [ * 6 2 _ _ _ _ (beep)]

2. Enter a single digit attention number (0-9) then press *. [ _ * (beep)]

3. Press 0# TOGETHER to end. [0# (beeeeeep)]

2.2.4 Single or Double Ring

Default setting is 1 (Double Ring).

Setting this for a double ring provides a unique ring so that a call from the 1812 is easily identified, or
the ring can be set to the standard single long ring.

1. Press * 6 3 and then enter the MASTER CODE. [ * 6 3 _ _ _ _ (beep)]

2. Press 1 * for a double ring OR press 0 * for a single ring. [ _ * (beep)]

3. Press 0# TOGETHER to end. [0# (beeeeeep)]

Page 24

1812-161-E-1-10

Advertising