PD-01 PROFIBUS-DP Module

DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED

32

Code Meaning

Corrective

actives

03 Illegal

data

value

The data value received in the
command message is not
available for the drives.

1. Check the parameter data (PWE2) in PKW

area, and refer the user manual of VFD series
Drives.

2. Check the PLC program to confirm the data

that transmitted to PD-01 from master is valid.

3. Re-supply power to PD-01.

04 Slave device failure

The drive is unable to perform the
requested action.

1. Check all data in PKW.
2. Re-supply power to PD-01.

VFD series Drives will not respond message to PD-01 if it receives an invalid message from
PD-01, but error code shown in the table below will be displayed on the digital keypad.

Code Meaning

Corrective

actives

05 Reserved

06 AC Drive is busy
07 Reserved

08 Reserved

09 Check sum is error
10 Time

out

11 Baud rate or protocol is invalid

12 Message is too short
13 Message is too long
14 Message contain invalid character

1. Please refer to section 4.2 in this manual

and check the setting of VFD series Drives.

2. If the error still exists, return it to factory.