23

N

I

C

D

B

ATTERY

C

HARGER WITH

R

ECONDITIONING

F

EATURE

MLPN: 45561 - 115V and 45562 - 230V

How to Recondition

1. Place the scanner into the

charge stand.

2. Push the stand tilt cup in

the extreme down position
to expose the hole for the
discharge cycle switch.

3. Use a pin to push the

discharge cycle switch
located beneath the hole.

4. When the discharge mode

is initiated the green LED
flashes.

R

ECOMMENDED

U

SE

To maintain charge capacity, the NiCd batteries must be discharged fully
before charging. We call this process reconditioning.

Recondition if:

The batteries were not used within 20 days

The batteries were not discharged (approximately two hours of

continuous operation) at least once a week

Low battery indicators:

Both LED’s on the scanner blink

The scanner quietly beeps twice while scanning

Recondition once a week if:

The batteries do not get discharged for more than 20%

(approximately ½ hour) of their capacity before recharging.

Recondition once every two weeks if:

The batteries do not get discharged for more than 50%

(approximately 1 hour) of their capacity before recharging.

Note: The day to day usage of the NiCd batteries will determine the

frequency of the discharges (reconditioning).

Charge State

CHG LED Status

Battery Absent

LED off

Charge Pending

LED on for 0.125sec, off for
1.375sec

Discharge-Before-
Charge

LED on for 1.375sec, off for
0.125sec

Fast-Charge

LED on

Charge Complete Top-
Off

LED on for 0.125 sec, off for
0.125sec

Figure 7: Reconditioning