Mxe control panel – Kemppi Promig 540R User Manual

Page 14

Advertising
background image

14 – Promig 540R, Promig 120R/0425

©

KEMPPI

OY

Promig 540R, Promig 120R/0423 – 15

©

KEMPPI

OY

4. MXE CONTROL PANEL

Operations of MXE control panel are described in manual delivered with MXE.

Exceptions to the operations of MXE in robot use:
- 4T start switch function is not active
- gun remote control is not active
- there are 63 active memory channels
Other functions related to robot use:
MXE panel can be used in normal local control by setting MEMORY OFF and LOCAL. Key

switch on machine front is turned to position MANUAL. All adjustments are set with the panel.

In this case start and stop of machine can be controlled with robot.
By setting MXE panel to REMOTE mode, wire feed speed/voltage or power/fine control can be

regulated with robot via analog lines.
Memory channels can be programmed as described in the operating manual of MXE panel.
When retrieving memory channels, you can choose with robot whether to use wire feed speed/

voltage or power/fine control values retrieved from memory, or whether these values are

controlled with robot via analog lines (see technical manual).
When controlling memory channels with robot, memory functions are to be set to MEMORY

ON mode. Key switch is turned to position AUTO.
Note! On memory channel 0 (= no memory channel selected) machine always retrieves memory

channel which was used last.

Advertising