Troubleshooting tips, Before you call for service, No soft water – most common problems – Diamond Power Products GXSF27B User Manual

Page 20

Advertising
background image

20

Before you call for service…

Troubleshooting Tips
Save time and money! Review the chart on this
page first and you may not need to call for service.

Problem

Possible Causes

What To Do

No soft water

Faucet or fixture where sample was

To conserve salt, the installer may have isolated some

taken not plumbed to soft water.

fixtures (outside faucets, toilets, etc.) from soft water.

NOTE: Be sure sample is from a faucet

From the outlet of the water softening system, trace the

that does not mix soft and hard water.

water flow path, in house plumbing. If soft water is not

For example, a single lever kitchen faucet,

directed to a faucet or fixture where wanted, consult

if the cold side is plumbed to hard water

a plumber.

No salt in the brine tank or

Check for a salt bridge or, if the tank is empty, refill with

salt bridged

recommended salt. Press (for 3 seconds) the TOUCH or
HOLD
button to start an immediate regeneration and restore
soft water supply.

Transformer unplugged at wall outlet or

Check for a loss of electrical power to the water

power cable to softener not connected.

softening system, due to any of these conditions and

Fuse blown or circuit breaker popped

correct as needed. With the power supply restored,

on circuit to electrical outlet.

observe the faceplate time display and read Program

Electrical outlet on a circuit that can

Memory section. NOTE: The electrical outlet for the softener

be switched off.

should be continuously live

so it cannot be accidentally

switched off.

Manual bypass valve in bypass position

Be sure the bypass valve stem is positioned properly, with the

knob in the OUT position. Observe instructions on the decal
at the end of the stem.

Valve drain hose pinched, plugged,

Any restriction in this drain hose may prevent proper

elevated too high or otherwise

operation of the nozzle and venturi and reduce or

restricted

prevent brine draw during regenerations.

Nozzle and venturi dirty, incorrectly

Refer to Cleaning the Nozzle and Venturi Assembly instructions.

assembled or damaged

With water pressure to the water softening system off,
take the nozzle assembly apart. Inspect, clean and
replace as needed. Any foreign particle(s), scratches,
nicks, etc., in the passages can prevent operation. Be sure
holes in the gasket are centered over holes in the housing.

NO SOFT WATER – Most Common Problems

:

Check the following before calling for service

Salt in softener...at least 1/3 full.
By pass valve in “Service” position. Knob should be in the OUT position.
Check hardness setting in control. Verify hardness of supply water. Water

hardness can vary throughout the year (see Programming the Control section).

Salt Bridge, water not in contact with salt (see Breaking a Salt Bridge section).

Advertising