Museum Technology Source KD-1 Proximity Switch User Manual

Kd-1 dimensions, Connecting kd-1 to external device

Advertising
background image

Control

Logic

Output

Transistor

NPN

Brown

Black

Blue

+V

Output

0 V

Supply Voltage: 12 to 30 VDC

@15 mA

Max Current: 100 mA
Max On State

Output Voltage: 1.5 V

Internal Reverse

Polarity Protection

Control

Logic

Output

Transistor

NPN

Brown

Black

Blue

+V

Output

0 V

Internal Reverse

Polarity Protection

Power Supply

10 to 30

VDC to

match

relay

+

-

Relay Coil

Diode such as 1N4004

must be placed as shown

across relay or solenoid

coil.

IMPORTANT

Cathode

Cathode

Anode

Anode

KD-1 Internal Circuit

External Circuit

Connecting KD-1 to External Device

KD-1 requires a supply voltage in the range of

12 to 30 volts DC. Current draw 15 mA (.015 Ampere)

The KD-1 will switch ON when a finger is held within

approximately 3/8 inch of the target. The KD-1 may

be mounted behind non-metallic material such as

Plex-glas or MDF. In general, this material should

be no thicker than 1/4 inch.

Connect to positive supply voltage

Connect to device to be activated

Conducts to common terminal when active

Connect to Negative of power supply.

Also connects of common of circuit being switched.

POSITIVE

NEGATIVE

KD-1 CAPACITANCE SWITCH

INSTALLATION SHEET

Museum Technology Source Inc.

Wilmington Massachusetts 01887

800-729-6873 978-657-3898

www.museumtech.com

March 2004

Limit current through output transistor

(Black lead) to 100 mA. Exceeding this

limit may result in damage to the KD-1

6' 6" Cord

.110" OD

KD-1 Dimensions

Revised April 4 2006

Advertising