background image

Form #43155040

-28-

May 2013

Heater Body

1/4-20 Locknut

(QTY-3 per flange)

Tube Flange

12 Radial Hole

Note: The wiring connection

diagram is located on the inside

access panel and inside the

junction box panel.

Tube Flange

Gasket

Exhaust Hood

(no starting collar necessary)

-Required for UNVENTED use-

4” x 6” Flue Pipe

Starting Collar

(for 180-250m BTU units only)

Flue Restrictor

Plate

Opening for

Electrical

Connection

Junction

Box

Draft Inducer

Wire Leads

(to L1 and L2 of the

control terminal

block)

4” Dia. Flue Pipe

Starting Collar

(for 40-175m BTU units only)

SJO Cable

3/8”

Connector

11.9)

LTS SERIES - INCLINED MOUNTING INSTRUCTIONS

These inclined mounting instruction relate to LTS series heaters (straight tubes) that do not utilize the elbow
accessory. These heaters have been tested and design certified by the CSA for 2”/12” pitch (10º) inclined
mounting of the heater from the control box to the draft inducer assembly as shown in the following diagram.

Speed Clips

Inclined Mounting

Reflector

Draft Inducer

Assembly

DETAIL A

These parts are included in the inclined mounting kit.

10 Deg.

Control

Box

Body Sections

Draft

Inducer

Advertising