13.5 Varmeca drives: three-phase connection diagram

Note: For single-phase standards, the power supply is connected to terminals L and N.

13.6 Varmeca drives: keypad indicator light display

Before switching on the Varmeca-30 motor, check that
electrical connections are correct and that any moving parts
are mechanically protected. The Varmeca-30 must not be
switched on with the protective cover removed.

Indicator

Status

Checks to be performed

Steady green
light

No trip
Mains present

Flashing green
light

Current limiting

Check that the motor is not overloaded or stalled

Flashing red
light

IGBT temperature
alarm
Motor overload
Braking resistor option
overload

Check that air can circulate around the motor fins

and Varmeca casing

The motor is overloaded: check the motor

current using an ammeter

Check that the deceleration ramp is long enough

for applications with high inertia

Steady red
light

Short-circuit of a
motor winding
Locked motor rotor
Faulty insulation of a
winding
I²t overheating
Internal fault
Undervoltage
Overvoltage

Check that no incident has occurred

Switch off and on again to clear the fault

Check the mains voltage

Check that the deceleration ramp is long enough

for applications with high inertia

If the fault ramains, consult the manufacturer