21 620RE and 620RE4 tube element loading

620RE element pumpheads are factory set to accept Watson-Marlow LoadSure tube
elements. Pumping performance will be adversely affected if LoadSure elements are
not used.

Disengage rollers

Locate one of the "D"-shaped flanges into the lower port. (The "D" flange ensures
that the element can only be loaded correctly).

Wrap the tube element around the disengaged rollers of the rotor.

Locate the second "D"-shaped flange into the upper port.

Ensure the flat face of each "D" flange sits flush to the flange sealing face of the
track.

Engage rollers

Close the guard and push it against the track until the latch engages.

Tube element loading