Flow rates

Note: Flow rates quoted have been rounded for simplicity, but are accurate to within 5% -
well within the normal tubing-tolerance variation of flow rate. They should therefore be
taken as a guide. Real flow rates in any application must be determined empirically.

620R

Tube bore

Tube number - #

rpm

Pressure (+)

Suction (-)

Flow rates: Marprene, Bioprene (l/min)

mm

6.4

9.6

12.7

15.9

inch

1/4

3/8

1/2

5/8

#

26

73

82

184

7-78 0.09-1.0

0.18-2.0

0.28-3.1

0.37-4.3

8-76 0.10-1.0

0.20-1.9

0.32-3.0

0.42-4.2

8-77 0.10-1.0

0.20-1.9

0.32-3.1

0.42-4.2

8-83

0.10-1.1 0.20-2.1 0.32-3.3 0.42-4.5

15-146

0.20-1.9 0.38-3.7 0.60-5.8 0.80-7.8

17-83

0.22-1.1 0.43-2.1 0.68-3.3 0.90-4.5

26-261

0.34-3.4 0.65-6.5 1.0-10 1.4-11

47-237

0.61-3.1

1.2-5.9 1.9-9.5 2.5-11

50-251

0.65-3.3 1.3-6.3 2.0-10 2.7-11

52-259 0.68-3.4 1.3-6.5 2.1-10

2.8-11

Flow rates: Marprene, Bioprene (USGPM)

mm

6.4

9.6

12.7

15.9

inch

1/4

3/8

1/2

5/8

#

26

73

82

184

7-78 0.02-0.3

0.05-0.5

0.07-0.8

0.10-1.1

8-76 0.03-0.3

0.05-0.5

0.08-0.8

0.11-1.1

8-77

0.03-0.3 0.05-0.5 0.08-0.8 0.11-1.1

8-83

0.03-0.3 0.05-0.5 0.08-0.9 0.11-1.2

15-146

0.05-0.5 0.10-1.0 0.16-1.5 0.21-2.1

17-83

0.06-0.3 0.11-0.5 0.18-0.9 0.24-1.2

26-261

0.09-0.9 0.17-1.7 0.27-2.8 0.37-3.0

47-237

0.16-0.8 0.31-1.6 0.50-2.5 0.67-2.9

50-251

0.17-0.9 0.33-1.7 0.53-2.7 0.72-3.0

52-259 0.18-0.9 0.34-1.7 0.55-2.7 0.75-3.0

Flow rates: Silicone (l/min)

mm

6.4

9.6

12.7

15.9

inch

1/4

3/8

1/2

5/8

#

26

73

82

184

7-78 0.08-0.9

0.19-2.1

0.29-3.3

0.38-4.8

8-76

0.10-0.9 0.22-2.1 0.34-3.2 0.44-4.7