Airmar B744V User Manual

Installation instructions, Junction box kit, Applications

Advertising
background image

17

-0

33

-0

2 re

v.

07

12

/14

/10

Applications

These instructions are for a replacement speed/temperature

insert only. Installing a new insert will NOT solve problems with
depth sounding or fish finding.

• Determine which instructions to follow, either A or B, by looking

at your multisensor. If your multisensor has one cable, follow
instructions A on page 2. If your multisensor has two cables—

one from the depth transducer and one from the speed/
temperature insert—follow instructions B on page 3.

• If these instructions are followed carefully:

• The connections will not corrode
• The strain relief grommets will be water resistant and provide

excellent cable retention.

Before Installing

1. Be sure your new speed/temperature insert is the correct

replacement. Compare the length of the new insert with the
original insert (ignore the cable). If the new insert is more than
3mm (1/8") longer or shorter than the original insert, return it. To
obtain the correct insert, see “ Replacement Parts” on the back
of your multisensor’s owner’s guide.

2. Check the multisensor’s connector at the echosounder for

corrosion. If the connector’s pins are corroded, clean them.
Then test the multisensor to see if the problem has been
corrected.

3. Check the speed and temperature functions of the new insert.

Connect it to the echosounder and spin the paddlewheel.
Check for a reading of several knots. Check for the approximate
air temperature. If there is no reading(s), check the connection
and repeat the test. If there is still no reading(s) or it is
inaccurate, return the product to your place of purchase.

Tools & Materials

Safety goggles
Dust mask
Pencil
Drill
Drill bit: 3mm or 1/8"
Screwdrivers: Phillips and blade
Box-cutter knife (zip-cable installation)
Cutting pliers
Masking tape
Marker
Wire strippers
Alcohol
Crimping pliers (nine or ten-wire cables)
Anti-fouling paint (water-based) (mandatory in salt water)
Silicone lubricant or petroleum jelly

Mounting Location

1. Remove the red cap from the junction box and set the contents

aside (see Figure 1).

2. Select a convenient dry mounting location along the

multisensor’s cable route, preferably 1–1.5 m (3–5') from the
multisensor but no more than 3m (10').

3. Position the junction box so the grommets are easily accessible

to the cable. Mark the location of the mounting holes.

4. At the marked location, drill two 3mm or 1/8" holes

approximately 10mm (3/8") deep. Do not fasten the junction
box in place at this time
.

INSTALLATION INSTRUCTIONS

connector

black sleeving

large diameter

sleeving

small diameter

sleeving

terminal block

tab (2)

grommet (4)

Figure 1. Junction box and contents

terminal

terminal screw

mounting screws

mounting

block

screws

(16)

screw (2)

cap

Copyright © 2002, 2009 Airmar Technology Corp.

WARNING: Always wear safety goggles and a dust

mask when installing to avoid personal injury.

CAUTION: High Voltage Charge

The depth transducer may be storing a high voltage

charge. Accidental discharge could destroy the speed

sensor.

IMPORTANT: Read the instructions completely

before proceeding with the installation. These

instructions supersede any other instructions in your

instrument manual if they differ.

Junction Box Kit

for Replacement Speed/Temperature Insert

Models: B44V, B66VL, B744V, B744VC, B744VL, B744VLC

Advertising
This manual is related to the following products: