Power Supplies for the BlackDiamond 12800 Series Switches

BlackDiamond 12800 Series Switches Hardware Installation Guide

151

Power Supplies for the BlackDiamond 12800 Series
Switches

This section lists specifications for the power supplies that are installed in the following BlackDiamond
switches:

BlackDiamond 12804 switch

BlackDiamond 12802 switch

Operating conditions

Operating temperature range 0° C to 40° C (32° F to 104° F)
Operating humidity:10% to 93% relative humidity, non-condensing
Operating altitude 0 to 3000 meters (0 to 9,850 ft)
Operational shock: 30 m/s

2

(3 g), 11 ms, 60 shocks

Operational random vibration: 5 to 500 Hz @ 1.5g rms

Storage & transportation
conditions (packaged)

Transportation temperature: –40° C to 70° C (–40° F to 158° F)
Storage and transportation humidity: 10% to 93% relative humidity,
non-condensing
Packaged shock (half sine):

<50 kg 180 m/s

2

(10 g), 6 ms, 600 shocks, modules

>50 kg 100 m/s

2

(6 g), 11 ms, 600 shocks, chassis

Packaged random vibration: 5 to 20 Hz @ 1.0 ASD w/–3dB/oct. from 20 to
200 Hz
Packaged sinusoidal vibration: 5 to 62 Hz, 5 mm/s velocity, 62 to 200 Hz,
0.2 G
Tilt: 22.5 degrees and return to position
14 drops minimum on sides & corners
@ 39.4" <20 lb (9 kg) modules
@ 19.7" <80 lb (36 kg) chassis

Table 26: AC SSI PS Model #60020/PS2336 (700/1200 W AC PSU)

For the BlackDiamond 12804 switch

Typical configuration

3 power supplies

Full configuration

6 power supplies

Input

Nominal input: 100 to 240 V

, 60/50 Hz, 10 A max

AC voltage input range: 90 to 264 V
Maximum input amperages:

7 A @ 200 V

(high-line)

10 A @ 90 V

(low-line)

AC line frequency: 47 to 63 Hz
PS input socket: IEC 320 C14
Minimum wire size: 16 AWG (1.31mm

2

) copper stranded

Output

DC output: 48 V

, 24 A/12 V

, 4 A (high-line)

48 V

, 13.5 A/12 V

, 4 A (low-line)

DC output power (W): 700 to 1200 W

Power supply cord selection

Refer to

“Selecting Power Supply Cords” on page 136

.

AC power supply input socket

IEC 320 C14

Minimum wire size

16 AWG (1.0mm

2

) copper stranded

(pre-approved cord set for county of use)

Operating conditions

Operating temperature: 0° C to 40° C
Storage temperature: –40° C to 70° C
Operating humidity: 10% to 90% relative humidity, non-condensing
Operational shock: 30 m/s

2

(3 g)

Table 25: BlackDiamond 12802 Switch Technical Specifications (Continued)

Advertising