Elk 982 User Manual

Cell-pack, Application, Features

Advertising
background image

P.O. Box 100 • Hildebran, NC 28637 USA • 828-397-4200 • 828-397-4415 FAX
http://www.elkproducts.com • email: [email protected]

Black

Red

* Note:

Battery (ELK-1250) &

Transformer (ELK-TRG1640)

Included with ELK-982K

Sold Separately for ELK-982

-

Optional hookup

for Transmission

Shunt (if available)

Battery
12 Volt

* See Note

Transceiver

12 Volts D.C.

Power Input

Bell / Alarm

Input

Refer to the Cellular Transceiver

Instructions for Connections

Cellular

Alarm Transceiver

+

-

+

Bell / Alarm output

-

+

LED Status Indicators

(Grn)(Red)
AC

DC

Indication

ON / ON

AC input is on / DC output is on. Normal.

OFF / ON

AC input is off / DC output is from Battery only. Step
down Transformer is defective or unplugged, or the
AC outlet is off. Battery will eventually discharge.

ON / OFF

AC input is on / DC output is off. The auto-reset
overload protector is likely open due to an overload
short circuit.

OFF / OFF

AC input is off / DC output is off.

AC

TRANSFORMER DC OUTPUT

AC DC

BATTERY

+

-

JP1
JP2

JP1 ON
JP2 OFF

E

L

K

-624

12V

PO

W

E

R

SU

PP

LY

LEDS

Line Fault output
Relay (contacts closed to
halt radio transmissions)

Control Panel

Do Not Move Jumpers

* See Note

Transformer

16.5 VAC

45 VA

- +

APPLICATION

The ELK-982(K) Cell-Pack is ideal for Cellular Alarm
Transceivers. It consists of a metal enclosure and 12 Volt
DC power supply/battery charger. It supplies 1 Amp
continuous current and 2.5 Amps peak for the brief high
current demands of the radio during transmission. The
design of the enclosure allows quick and easy field
mounting of the transceiver and antenna.

Cell-Pack

Power Supply, and Enclosure for

Cellular Alarm Transceiver

03/04

For Technical Support on the Numerex Technologies
Digicell Transceiver, call 888-987-5465.

FEATURES

• Supplies 12 Volts D.C. Power for Transceiver
• Current: 2.5A Peak, 1A Continuous
• Heavy Duty Metal Enclosure

INSTALLATION

1. Mount transceiver in top right corner by sliding

antenna thru rubber grommet and securing the
bottom using hardware supplied. (see page 2)

2. Mount the ELK-P624 power supply board into the

enclosure as shown.

3. Wire as per the Cellular Transceiver instructions.
4. Connect Transformer and Battery after all wiring

is complete.

OPERATION

This hookup example shows the Transmission Shunt
Mode of operation. Control panel's that have phone
line fault monitoring will halt radio transmissions while
the phone line is good. Relay contacts on the control
panel will be closed to shunt any possible radio
transmissions.

If your control does not have line fault monitoring,
see ELK-981 which provides line fault monitoring
with power supply.

Features and Specifications subject to change without notice.

Includes Battery
& Transfomer

ELK-982K

ELK-982

Advertising