Emerson 16E09-101 User Manual

Precautions, Description, Save these instructions for future use! warning

Advertising
background image

CONTENTS

Basic Description ........................................................ 1
Precautions ................................................................. 1
Installation ................................................................... 2
Wiring .......................................................................... 3
User Menu .................................................................. 4
Operation .................................................................... 5
Specifications .............................................................. 7
Troubleshooting ........................................................... 8

www.white-rodgers.com

www.emerson.com

PRECAUTIONS

16E09-101

Universal Electronic Temperature Control

PART NO. 37-6857G

Replaces 37-6857F

1016

INSTALLATION AND

OPERATION INSTRUCTIONS

DESCRIPTION

The 16E09-101 is a single stage electronic temperature con-
trol, with a Nema 1 rated enclosure, and can be used for most
applications within the temperature control range of -40° to
220°F, (-40° to 104°C). The control has an SPDT (Single Pole
Double Throw) output load relay.
The control has user options to control differential, anti-short
cycle delay, set back, offset, alarms and more. It includes an
NTC (Negative Temperature Coefficient) thermistor tempera-
ture sensor, and can be used with certain other NTC or PTC
(Positive Temperature Coefficient) thermistors that meet the
specified resistance vs. temperature specifications. See the
tables on page 7.
The control can fit many applications, which range from
refrigeration to heating due to the wide temperature range of
the control stated above. Typical applications include walk-
in freezers, beverage coolers, supermarket display cases
for flowers, produce, meats, convenience store refrigerated
cases, food warmers, boiler control, and certain industrial
applications.

Save these instructions for future use!

WARNING

!

16E09-101 Optional Accessories / Service Items:
Immerson Well .................................................... F89-0286
Replacement 7.5' NTC Remote Sensor .............. F136-0114
Well Heat Transfer Compound ............................. F145-0163

Failure to read and follow all instructions carefully before

installing or operating this control could cause personal
injury and/or property damage.

To prevent electrical shock, personal injury and/or

equipment damage, disconnect electric power to system
at main fuse or circuit breaker box prior to installation
or service.

To prevent scald injury, do not use this control to

heat water for bathing, washing, hot tub or similar
applications.

Where failure of this control may result in personal

injury and/or property damage, additional alarms or limit
controls must be installed.

This control is a temperature control and is not to be

used as a temperature limit control.

Advertising