InstructIons for:

SUPERCHARGE

bAttERy

CHARGERS

IMPORTANT: PLEASE READ tHESE INStRUCtIONS CAREFULLy. NOtE tHE SAFE OPERAtIONAL REQUIREMENtS, WARNINGS AND CAUtIONS. USE tHIS

PRODUCt CORRECtLy AND WItH CARE FOR tHE PURPOSE FOR WHICH It IS INtENDED. FAILURE tO DO SO MAy CAUSE DAMAGE OR PERSONAL INJURy,

AND WILL INVALIDAtE tHE WARRANty. PLEASE REtAIN tHESE INStRUCtIONS FOR FUtURE USE.

thank you for purchasing a sealey product. Manufactured to a high standard this product will give you years of trouble free performance if these instructions are carefully followed and the

product is correctly maintained.

SUPERCHARGE 10/1.V4 SUPERCHARGE 15/1.V4 SUPERCHARGE 30/1.V4 SUPERCHARGE 40/1.V4

1.1.

ELECtRICAL SAFEty

WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and

any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of

appropriate safety devices. A residual current circuit Breaker (rccB) should be incorporated in the main distribution board. We also

recommend that a residual current Device (rcD) is used. It is particularly important to use an rcD with portable products that are

plugged into a supply which is not protected by an rccB. If in any doubt consult a qualified electrician. You may obtain a residual

current Device by contacting your sealey dealer.

You must also read and understand the following instructions concerning electrical safety.

1.1.1. the Electricity at Work Act 1989 requires that all portable electrical appliances, if used on business premises, are tested by a qualified

electrician, using a Portable Appliance tester (PAt), at least once a year.

1.1.2. the Health & safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances

and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.

1.1.3. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. see 1.1.1. and 1.1.2.

and use a Portable Appliance tester.

1.1.4. Ensure that cables are always protected against short circuit and overload.

1.1.5. regularly inspect power supply cables and plugs for wear or damage and check all

connections to ensure that none is loose.

1.1.6. Important: Ensure that the voltage marked on the appliance matches the power supply

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7. Do not pull or carry the appliance by the power cable.

1.1.8. Do not pull the plug from the socket by the cable.

1.1.9. Do not use worn or damaged cables, plugs or connectors. Immediately have any faulty

item repaired or replaced by a qualified electrician. When a Bs 1363/A uK 3 pin plug is

damaged, cut the cable just above the plug and dispose of the plug safely.

fit a new plug according to the following instructions (uK only).

a) connect the GrEEn/YELLoW earth wire to the earth terminal ‘E’.

b) connect the BroWn live wire to the live terminal ‘L’.

c) connect the BLuE neutral wire to the neutral terminal ‘n’.

d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation extends

beyond the cable restraint and that the restraint is tight.

Double insulated products, which are always marked with this symbol , are fitted with live (brown) and neutral (blue) wires only.

to rewire, connect the wires as indicated above -

Do not connect either wire to the earth terminal.

1.1.10. Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure

that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket

with your electrician.

1.1.11. If an extension reel is used it should be fully unwound before connection. A reel with an rcD fitted is preferred since any appliance

plugged into it will be protected. the cable core section is important and should be at least 1.5mm², but to be absolutely sure that the

capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use

of 2.5mm² section cable.

1.2.

GENERAL SAFEty

WARNING! Disconnect the charger from the mains power before servicing or performing any maintenance.

Disconnect the charger from the mains power before connecting to, or disconnecting from, the battery.

Maintain the

charger in good condition (use an authorised service agent only).

WARNING! charger has components such as switches and relays which may cause sparks or arcs.

When using the charger in a garage or workshop, make sure it is in a safe location.

Keep the charger clean for best and safest performance.

WARNING! Ensure there are no sources of flammable ignition near the work area i.e. naked flames,

cigarettes, flame heaters etc as the charging process produces explosive gases.

WARNING! Ensure the working area is well ventilated as the gases produced are flammable and

harmful if inhaled.

Locate the charger in a suitable working area. Keep area clean and tidy and free from unrelated

materials and ensure there is adequate lighting.

Wear approved safety eye protection (standard spectacles are not adequate).

remove ill fitting clothing. remove ties, watches, rings, and other loose jewellery, and contain long hair.

read vehicle manufacturer’s instructions manual to check for any specific battery charging information.

Disconnect the battery from the vehicle and move it to a safe, dry level area for charging. If the battery can not be removed from the

vehicle refer to manufacturer’s hand book.

check the electrolyte fluid level in the battery is above the plates. If not add distilled water to cover them by 5 - 10mm. Do not

touch the battery fluid as it is corrosive

clean the charger clamps and battery terminals to remove any oxidation before connecting charger to battery .

1. SAFEty INStRUCtIONS

FUSE RAtING 13 AMP

Blue

Neutral

Wire

Yellow & Green

Earth Wire

Cable

Restraint

Brown

Live

Wire

Original Language Version

suPErcHArGE10/4.V4, 15/1.V4, 30/1.V4, 40/1.V4 Issue: 2 - 08/03/10