Energizer 346 User Manual

Energizer 346, Product datasheet, Temperature characteristics

Advertising
background image

Chemical System:

Silver Oxide (Zn/Ag

2

O)

Nominal Voltage:

1.55 Volts

Typical Capacity:

9.5 mAh* (to 1.3 volts)

Capacity Test:

100K ohm continuous drain at 21°C

Typical Weight:

0.24 grams (0.008 oz.)

Typical Volume:

0.06 cubic centimeters (0.003 cubic inch)

Impedance (40 Hz):

30 to 40 ohms

Load

Cutoff

1.3V

(ohm)

(hours)

100K

594

Typical Performance at Low Discharge Rates

Temperature Characteristics

SILVER OXIDE

Specifications

Cross Section

* Varies according to the applied load, temperature, and cutoff voltage.

Industry Standard Dimensions

ENERGIZER 346

©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.

Important Notice

This datasheet contains typical information specific to products manufactured at the time of its publication.

Continuous

0.016

at 1.55V

(milliamperes)

Schedule

Typical Drains

Typical Performance at 21°C (70°F)

mm (inches)

Typical Discharge Characteristics

PRODUCT DATASHEET

1-800-383-7323 / USA
1-800-383-7323 / CANADA

1-800-383-7323 USA/CAN

www.energizer.com

Schedule: Continuous

Typical Drain @1.55V:

0.016 milliamperes

Load: 100K ohm

1.0

1.1

1.2

1.3

1.4

1.5

1.6

1.7

0

125

250

375

500

625

Service, Hours

V

o

lt

a

g

e

, CCV

DESIGNED FOR USE ON CONTINUOUS LOW DRAIN

Service Effects

0

25

50

75

100

125

-20

0

20

40

Temperature (C)

Se

rv

ic

e

(%

)

Storage Effects

60

70

80

90

100

0

2

4

6

8

10

12

Storage Time (yrs)

Se

rv

ic

e

(%

)

40°C

20°C

0°C

Anode Cap
Gel Anode

Gasket
Can
Separator

Cathode

7.90 (0.311)
7.62 (0.300)

R0.40 (0.016) Ref.

Typical

0.01 (0.0004) Minimum Ref.
(applies to top edge of gasket or
edge of crimp, whichever is higher)

5.30 (0.209) Ref.

Typical

1.14 (0.045)

1.30 (0.051)

1.25 (0.049) Ref.
1.05 (0.041) Ref.

0.15 (0.006) Maximum Ref.
Permissible deflection from a flat

Form No. EBC - 4317D

Page 1 of 1

Advertising